An NMR Phased Array for Human Cardiac 31P Spectroscopy
- 1 November 1992
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 28 (1) , 54-64
- https://doi.org/10.1002/mrm.1910280106
Abstract
A four-coil phased-array 31P NMR receiver was designed and tested for human cardiac applications, to determine whether the combination of relatively high signal-to-noise ratio (SNR) and large field of view produced in 1H imaging is also realized for in vivo 31P spectroscopy. Spectra were acquired in parallel from an array of four overlapping 6.5-cm surface coils using one- and two-dimensional phase-encoding pulse sequences and were optimally combined to yield composite spectroscopic images. The phased array was found to generate useful 31P spectra from a 2.5-fold wider lateral region around the anterior myocardium than a single receiver of the same size as the array elements, with no increase in imaging time. In addition, the sensitive depth was increased by up to 2 cm over that of a single coil. Spectra could be acquired in roughly 15 min from a region extending to the middle of the heart, with voxel sizes of 2 X 2 X 4 cm3. For the average heart voxel, the SNR of the combined spectrum was higher than that of the best spectrum from any one coil in the array by 30%, with some voxels showing an increase as high as 60%.© 1992 Academic Press,Inc.Keywords
This publication has 15 references indexed in Scilit:
- Noise correlations exist for independent RF coilsMagnetic Resonance in Medicine, 1992
- Altered myocardial high-energy phosphate metabolites in patients with dilated cardiomyopathyAmerican Heart Journal, 1991
- Noise correlationMagnetic Resonance in Medicine, 1991
- 31P Spectroscopic localization using pinwheel NMR excitation pulsesMagnetic Resonance in Medicine, 1991
- Regional Myocardial Metabolism of High-Energy Phosphates during Isometric Exercise in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1990
- Phosphate metabolite imaging and concentration measurements in human heart by nuclear magnetic resonanceMagnetic Resonance in Medicine, 1990
- In vivo phosphorus-31 spectroscopic imaging in patients with global myocardial diseaseThe American Journal of Cardiology, 1990
- Spatial localization in two dimensions using NMR designer pulsesJournal of Magnetic Resonance (1969), 1989
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Parallel image acquisition from noninteracting local coilsJournal of Magnetic Resonance (1969), 1986