The Limitations of MALDI-TOF Mass Spectrometry in the Analysis of Wide Polydisperse Polymers
- 31 August 2000
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (19) , 4568-4576
- https://doi.org/10.1021/ac0002745
Abstract
Average molecular weight determination of polymers with polydispersities greater than 1.2 is an ongoing challenge in the field of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Mass discrimination effects observed in the analysis of these polymers have been attributed to sample preparation, desorption/ionization, and instrumental factors. In an effort to separate these factors, we studied poly(methyl methacrylate) (PMMA) standards using two different ion detection systems installed on the same time-of-flight mass analyzer. Equimass blends of narrow PMMA standards were used to simulate a polymer with a wide polydispersity. MALDI-MS analysis was also performed on a PMMA standard with a polydispersity of 1.7. All samples were analyzed by size exclusion chromatography for comparison. Although sample preparation and ionization/desorption factors were found to influence the spectral appearance of the MMA distributions, we demonstrate that, under similar sample preparation and instrument conditions, different ion detection systems produce different results for synthetic polymer blends. The differences in the detector responses for the blends and wide polydisperse standard arise from several factors related to the ion detection system: (1) detection mechanisms, (2) saturation effects, and (3) signal-to-noise limitations.Keywords
This publication has 15 references indexed in Scilit:
- A new procedure for quantitative correction of matrix-assisted laser desorption/ionization time-of-flight mass spectrometric responseRapid Communications in Mass Spectrometry, 1998
- Instrumental effects in the analysis of polymers of wide polydispersity by MALDI mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Why Does Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry Give Incorrect Results for Broad Polymer Distributions?Rapid Communications in Mass Spectrometry, 1996
- A charge detector for time-of-flight mass analysis of high mass ions produced by matrix-assisted laser desorption/ionization (MALDI)International Journal of Mass Spectrometry and Ion Processes, 1996
- Degradation and selective desorption of polymer can cause uncertainty in MALDI (matrix-assisted laser desorption ionisation) measurementsPolymer Degradation and Stability, 1996
- Mass Discrimination Effects in an Ion Detector and Other Causes for Shifts in Polymer Mass Distributions Measured by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass SpectrometryMacromolecules, 1996
- Detection of large molecular ions by secondary ion and secondary electrom emissionInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Surface secondary electron and secondary ion emission induced by large molecular ion impactsInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Secondary-ion and electron production from surfaces bombarded by large polyatomic ionsRapid Communications in Mass Spectrometry, 1992
- Secondary‐ion generation from large keV molecular primary ions incident on a stainless‐steel dynodeRapid Communications in Mass Spectrometry, 1992