Adverse effect of plasma exchange on anti-D production in rhesus immunisation owing to removal of inhibitory factors.
- 28 June 1980
- Vol. 280 (6231) , 1569-1571
- https://doi.org/10.1136/bmj.280.6231.1569
Abstract
Intensive plasma exchange was used to reduce the maternal anti-D concentration in case of severe rhesus haemolytic disease. Initially the concentration fell from 30 to 4 IU/ml, but after six exchanges it increased to 490 IU/ml despite continued exchanges, and intrauterine fetal death eventually ensued. The increase in the rate of maternal anti-D production coincided with, and may have resulted from, removal of plasma immuno-regulatory factors that inhibited in-vitro lymphocyte functions. These results that the role of plasma exchange in haemolytic disease of the newborn is more complex than simply removing the antibody and that further investigations are needed.Keywords
This publication has 8 references indexed in Scilit:
- Anti‐Autologous Erythrocyte Plaque‐Forming Cells in PregnancyVox Sanguinis, 1978
- Development of Rh‐Specific Maternal Autoantibodies Following Intensive Plasmapheresis for Rh Immunisation during PregnancyVox Sanguinis, 1977
- INTENSIVE ANTENATAL PLASMAPHERESIS IN SEVERE RHESUS ISOIMMUNISATIONThe Lancet, 1975
- Plasma Exchange in the Treatment of Immune DiseaseTransfusion, 1975
- CONTINUOUS-FLOW EXCHANGE-PLASMAPHERESIS IN SEVERE RHESUS ISOIMMUNISATIONThe Lancet, 1974
- Manipulative and inherent errors in anti-D quantitation using the AutoAnalyzerJournal of Clinical Pathology, 1972
- INTENSIVE PLASMAPHERESIS AS A THERAPEUTIC MEASURE IN RHESUS-IMMUNISED WOMENThe Lancet, 1970
- Intense plasmapheresis in the pregnant Rh-sensitized womanAmerican Journal of Obstetrics and Gynecology, 1968