Orthogonal Ventricular Electrogram Sensing
- 1 May 1983
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 6 (3) , 761-768
- https://doi.org/10.1111/j.1540-8159.1983.tb05337.x
Abstract
Inappropriate demand pacing is most commonly due to improper ventricular electrogram sensing. Filters and programmable sensitivities improve electrogram sensing of conducted beats, but paced electrograms cannot be sensed by conventional unipolar or bipolar systems. A permanent pacing lead with a standard tip electrode and three orthogonal 0.8 mm2 sensing electrodes located circumferentially 2 cm proximal to the pacing tip was tested in 22 patients. The tip electrode was placed in the right ventricular apex in standard pacing position. Orthogonal electrodes were not in contact with ventricular myocardium. Orthogonal ventricular electrograms from 54 electrode pairs were compared with unipolar tip electrograms during conducted rhythms and paced beats. Tip ventricular electrograms averaged 12.8 mV with 3.04 mVT waves. Orthogonally recorded ventricular electrograms during conducted beats averaged 8.86 mV with T waves of 1.57 mV. During pacing, tip ventricular electrograms were obscured by the stimulus artifact and repolarization events. Orthogonal ventricular electrograms, however, demonstrated small discrete stimuli of 1.99 mV followed by discrete ventricular electrograms of 9.19 mV and T waves of 1.9 mV. Orthogonal ventricular electrograms compared favorably with contacting tip electrograms during conducted beats and provided a redundant sensing capability. During pacing, orthogonal ventricular electrograms allowed the capability for capture verification. A new pacing catheter allows for improved ventricular electrogram sensing and capture verification.Keywords
This publication has 18 references indexed in Scilit:
- A New Orthogonal Lead for P Synchronous PacingPacing and Clinical Electrophysiology, 1981
- Myopotential Inhibition of Unipolar QRS‐inhibited (VVI) Pacemakers, Assessed by Ambulatory Holter Monitoring of the ElectrocardiogramPacing and Clinical Electrophysiology, 1980
- Cardiac Electrodes and Electrograms: Some New Observations and ConcernsPacing and Clinical Electrophysiology, 1980
- A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.Circulation, 1977
- Irregular recycling of demand pacemakers from borderline electrographic signalsAmerican Heart Journal, 1971
- Evaluation of normal and abnormal sensing functions of demand pacemakersThe American Journal of Cardiology, 1971
- The failure of triggered pacemakersAmerican Heart Journal, 1971
- Chest-wall stimulation: A method of demand QRS-blocking pacemaker suppression in the study of arrhythmiasAmerican Heart Journal, 1971
- A Mechanism for "False" Inhibition of Demand PacemakersCirculation, 1970
- Endocardial Electrograms from Pacemaker CathetersCirculation, 1968