Detection and prevention of hepatitis C in dialysis patients and renal transplant recipients. A long‐term follow up (1989–January 1997)
Open Access
- 1 February 2002
- journal article
- research article
- Published by Wiley in Journal of Internal Medicine
- Vol. 251 (2) , 119-128
- https://doi.org/10.1046/j.1365-2796.2002.00938.x
Abstract
Almroth G, Ekermo B, Månsson A‐S, Svensson G, Widell A. (University Hospital of Linköping; University Hospital of Malmö, Sweden) Detection and prevention of hepatitis C in dialysis patients and renal transplant recipients. A long‐term follow up (1989–January 1997). J Intern Med 2002; 251: 119–128. Background. Hepatitis C is frequent problem in dialysis wards. Design. A long time (1989–97) follow up of hepatitis C virus (HCV) infection in a Swedish nephrology unit was performed with anti‐HCV screening, confirmatory antibody tests, viral RNA detection and molecular characterization. Case histories were reviewed with focus, onset of infection, liver morbidity and mortality. Results. In October 1991, 10% (19 of 184) of the patients in the unit (haemodialysis‐, peritoneal dialysis and transplanted patients) were verified or suspected HCV carriers, whilst the number at the end of 1996 was 8% (13 of 157). Most patients were infected before 1991 but only in one case from a known HCV‐infected blood donor. No new HCV infections associated with haemodialysis occurred during the study period. A total of 13 of 24 viremic patients had HCV genotype 2b, a pattern suggesting nosocomial transmission. This was further supported by phylogenetic analysis of HCV viral isolates in seven. HCV viremia was also common in patients with an incomplete anti‐HCV antibody pattern as 8 of the 12 indeterminant sera were HCV‐RNA positive. Conclusions. Awareness, prevention, identification of infected patients and donor testing limited transmission. Indeterminant recombinant immunoblot assays (RIBA)‐results should be regarded with caution as a result of the relative immunodeficiency in uremic patients. Our data indicate nosocomial transmission in several patients.Keywords
This publication has 42 references indexed in Scilit:
- Autoclaving eliminates hepatitis C virus from a hemodialysis monitor contaminated artificiallyJournal of Medical Virology, 1999
- Universal precautions prevent hepatitis C virus transmission: A 54 month follow-up of the Belgian multicenter studyKidney International, 1998
- Undiagnosed hepatitis C virus infection in hemodialysis patients: Value of HCV RNA and liver enzyme levelsKidney International, 1996
- Nosocomial Hepatitis C in Dialysis UnitsNephron, 1996
- Further Evidence for Nosocomial Spread of Hepatitis C Virus Infection in Hemodialysis UnitsNephron, 1996
- Detection of Hepatitis C Virus in Dialysate and in Blood Ultrafiltrate of HCV-Positive PatientsNephron, 1994
- Evidence against Transmission of Hepatitis C Virus through Hemodialysis Ultrafiltrate and Peritoneal FluidNephron, 1994
- Hepatitis C virus RNA in blood donor sera detected by the polymerase chain reaction: Comparison with supplementary hepatitis C antibody assaysJournal of Medical Virology, 1991
- Antibody Responses to Hepatitis C Virus and Its Modes of Transmission in Dialysis PatientsNephron, 1991
- Chronic hepatitis in end-stage renal disease: Comparison of HBsAg-negative and HBsAg-positive patientsKidney International, 1985