Real Time Bunch Length Measurements in the SLC Linac
- 1 January 1985
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 32 (5) , 2006-2008
- https://doi.org/10.1109/tns.1985.4333796
Abstract
The longitudinal charge distribution of bunches accelerated in the Stanford Linear Collider (SLC) linac will strongly affect the performance of the Collider. Bunch lengths are chosen in a balance between the deleterious effects of longitudinal and transverse wakefields. The former impacts on the beam energy spread whereas the latter is important to the transverse emittance. Two bunch length measurement ports have been installed in the SLC linac: one in the injector region and one after the emittance damping ring to linac reinjection point. These ports utilize a fused quartz Cerenkov radiator in conjunction with an electrooptic streak camera to permit real time monitoring of single s-band buckets with a resolution of several picoseconds. The design of the radiators and light collection optics is discussed with an emphasis on those issues important to high resolution. Experimental results are presented.Keywords
This publication has 5 references indexed in Scilit:
- Observations of Accelerated High Current Low Emittance Beams in the SLC LinacIEEE Transactions on Nuclear Science, 1985
- A New Timing System for the Stanford Linear ColliderIEEE Transactions on Nuclear Science, 1985
- Picosecond resolution of a Cerenkov cell-streak camera arrangement for monitoring charged particle bunchesReview of Scientific Instruments, 1980
- Optimization of isolated electron pulses in the picosecond range from a linear accelerator using a streak camera–TV diagnostic systemReview of Scientific Instruments, 1976
- Time Resolution of an Image Converter Camera in Streak OperationThe Journal of Photographic Science, 1969