An Evaluation of Fibrin Tissue Adhesive Concentration and Application Thickness on Skin Graft Survival
Open Access
- 1 November 2000
- journal article
- research article
- Published by Wiley in The Laryngoscope
- Vol. 110 (11) , 1931-1935
- https://doi.org/10.1097/00005537-200011000-00031
Abstract
Objectives To e‐amine the effects of fibrinogen concentration and application thickness of fibrin tissue adhesive on skin graft survival.Study Design Prospective controlled study.Methods Ten domestic pigs were included in the study. A 20 − 5‐cm area of skin was harvested bilaterally along the flanks of the animals using a Padgett dermatome. The harvested grafts were trimmed into four 4 − 4‐cm squares. Donor sites were treated according to group assignment and the non‐meshed grafts were placed on the side opposite their initial orientation and secured with staples. Both single‐ and multiple‐donor human fibrin tissue adhesive preparations, with low and high average fibrinogen concentrations of 30 mg/mL and 60 mg/mL, were used. Adhesive preparations were applied in either a thin layer (0.015 mL/cm2) or a thick layer (0.06 mL/cm2) using a spray applicator. A constant thrombin concentration of 10 U/mL was used in the study. No adhesive was used in the control group and grafts were stabilized with staples. No topical dressings were applied to any of the treatment sites. Animals were sacrificed 4 weeks after graft application.Results Based on statistical analysis, thickness of adhesive application had a significant effect on skin graft survival. Percent mean graft survival in the control and thin application groups was found to be 92% and 97.8% respectively; the mean survival rate in the thick application group was 63.1%. Fibrinogen concentration, when evaluated independently within the thin and thick application groups, was found to have no significant effect on graft survival.Conclusion Independent of fibrinogen concentration, a thin layer of fibrin tissue adhesive, when applied between two opposing surfaces, does not interfere with and may support the healing process, whereas a thick layer of adhesive inhibits skin graft healing.Keywords
This publication has 18 references indexed in Scilit:
- Microvascular Anastomoses Utilizing New Intravascular StentsAnnals of Plastic Surgery, 1994
- Cerebrospinal fluid leak following acoustic neuroma removalThe Laryngoscope, 1994
- Experimental and Clinical Applications of Fibrin GluePlastic and Reconstructive Surgery, 1991
- The use of fibrin glue in intracranial procedures: Preliminary resultsThe Laryngoscope, 1990
- Application of Autologous Fibrin Glue in Burn WoundsJournal of Burn Care & Rehabilitation, 1989
- Use of Fibrin Glue in Thoracic SurgeryThe Annals of Thoracic Surgery, 1985
- A New Method of Skin Graft AdhesionScandinavian Journal of Plastic and Reconstructive Surgery, 1983
- Fibrin: Structure and InteractionsSeminars in Thrombosis and Hemostasis, 1982
- Why Do Skin Grafts Fail?Plastic and Reconstructive Surgery, 1979
- Ueber Wirkungen des FibrinsDeutsche Medizinische Wochenschrift (1946), 1909