Evaluation of a 10-minute Comprehensive MR Imaging Examination of the Upper Abdomen
- 1 April 1999
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 211 (1) , 189-195
- https://doi.org/10.1148/radiology.211.1.r99ap32189
Abstract
To determine whether a 10-minute magnetic resonance (MR) imaging examination of the upper abdomen provides sufficiently comprehensive information to replace a longer MR protocol. Images obtained with selected breathing-independent and breath hold MR sequences, with 2 minutes of total acquisition time and an estimated 10 minutes of total study time, in consecutive MR examinations of the upper abdomen in 72 patients (age range, 23-87 years) were retrospectively reviewed in a blinded fashion by two separate interpreters. Determination was made of major and minor findings, and the two separate retrospective interpretations and the prospective clinical interpretation were correlated by using kappa statistics. Surgical and clinical findings were also correlated with imaging findings. In 61 patients, all major and minor findings were identical in the original clinical interpretation and the two retrospective readings. In 66 patients, the major findings were identical in these three readings. Close agreement was present between the two separate retrospective readings and the prospective clinical interpretation (kappa = 0.49-1.00). The findings suggest that the diagnostic information provided by a shortened MR imaging protocol that includes breath-hold and breathing-independent sequences is in close agreement with lengthier MR protocols. The advantages of a shortened protocol include increased patient throughput and decreased study cost.Keywords
This publication has 16 references indexed in Scilit:
- Liver lesion detection, characterization, and effect on patient management: Comparison of single‐phase spiral CT and current MR techniquesJournal of Magnetic Resonance Imaging, 1997
- Ultrafast Magnetic Resonance Imaging Improves the Staging of Pancreatic TumorsAnnals of Surgery, 1997
- Liver metastases: improved detection with dynamic gadolinium-enhanced MR imaging?Radiology, 1997
- Pancreatic ductal adenocarcinoma: preoperative assessment with helical CT versus dynamic MR imaging.Radiology, 1997
- Pancreatic masses with inconclusive findings on spiral CT: Is there a role for MRI?Journal of Magnetic Resonance Imaging, 1996
- T2-weighted MR imaging of the abdomen: fast spin-echo vs conventional spin-echo sequences.American Journal of Roentgenology, 1994
- Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.American Journal of Roentgenology, 1993
- Multisection FLASH: method for breath-hold MR imaging of the entire liver.Radiology, 1992
- Renal lesions: controlled comparison between CT and 1.5-T MR imaging with nonenhanced and gadolinium-enhanced fat-suppressed spin-echo and breath-hold FLASH techniques.Radiology, 1992
- T1-weighted sequences for MR imaging of the liver: comparison of three techniques for single-breath, whole-volume acquisition at 1.0 and 1.5 T.Radiology, 1991