Investigation of secondary neutron dose for dynamic MLC IMRT delivery
- 2 March 2005
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 32 (3) , 786-793
- https://doi.org/10.1118/1.1861162
Abstract
Secondary neutron doses from the delivery of 18 MV conventional and intensity modulated radiation therapy (IMRT) treatment plans were compared. IMRT was delivered using dynamic multileaf collimation (MLC). Additional measurements were made with static MLC using a primary collimated field size of 10 x 10 cm2 and MLC field sizes of 0 x 0, 5 x 5, and 10 x 10 cm2. Neutron spectra were measured and effective doses calculated. The IMRT treatment resulted in a higher neutron fluence and higher dose equivalent. These increases were approximately the ratio of the monitor units. The static MLC measurements were compared to Monte Carlo calculations. The actual component dimensions and materials for the Varian Clinac 2100/2300C including the MLC were modeled with MCNPX to compute the neutron fluence due to neutron production in and around the treatment head. There is excellent agreement between the calculated and measured neutron fluence for the collimated field size of 10 x 10 cm2 with the 0 x 0 cm2 MLC field. Most of the neutrons at the detector location for this geometry are directly from the accelerator head with a small contribution from room scatter. Future studies are needed to investigate the effect of different beam energies used in IMRT incorporating the effects of scattered photon dose as well as secondary neutron dose.Keywords
This publication has 13 references indexed in Scilit:
- Monte Carlo simulation and experimental evaluation of photoneutron spectra produced in medical linear acceleratorsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2003
- Cancer Statistics, 2003CA: A Cancer Journal for Clinicians, 2003
- Primary radiation therapy for localized prostate cancerUrologic Oncology: Seminars and Original Investigations, 2002
- The effect of beam energy and number of fields on photon-based IMRT for deep-seated targetsInternational Journal of Radiation Oncology*Biology*Physics, 2002
- BUMS—Bonner sphere Unfolding Made Simple: an HTML based multisphere neutron spectrometer unfolding packageNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Performance of Multisphere Spectrometry SystemsRadiation Protection Dosimetry, 1998
- Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Choice of optimum megavoltage for accelerators for photon beam treatmentInternational Journal of Radiation Oncology*Biology*Physics, 1986
- The response of bonner spheres to neutrons from thermal energies to 17.3 MeVNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1985
- New Methods for Measuring Neutron Spectra with Energy from 0.4 eV to 10 MeV by Track and Activation DetectorsNuclear Technology, 1977