Fiber-Optic Luminescent Sensors with Composite Oxygen-Sensitive Layers and Anti-Biofouling Coatings
- 19 September 2001
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (21) , 5150-5156
- https://doi.org/10.1021/ac015517n
Abstract
Anti-biofouling polymers containing phosphorylcholine (PC)-substituted methacrylate units have been prepared by copolymerization with dodecyl methacrylate and used to coat luminescent oxygen sensors. Nanometer-sized coatings of such materials are shown to reduce significantly the adhesion of marine bacteria (more than 70%) and thrombocytes (more than 90%) to the surface of tris-(4,7-diphenyl-1,10-phenanthroline)ruthenium(II)-doped silicone layers. A thorough analytical characterization of both the PC-coated and the uncoated dyed films has demonstrated that the anti-biofouling layers do not alter dramatically the performance of the fiber-optic oxygen sensors in aqueous media and are mechanically stable for more than one year of continuous immersion. The slope of the linear calibration plots in the 0-8 mg L(-1) oxygen concentration range (ca. 1.0 L mg(-1)) decreases 8-11% after applying the 50-nm protective layer with no change in the sensor precision (1.1-1.9% RSD, n = 6). The response time of the 200-microm O2-sensitive layers (1.5-6 min) increases up to 2-fold, depending on the nature of the PC polymer used, but the temperature effect on the sensor response (0.020 L mg(-1) degrees C(-1)) remains essentially unchanged. Oxygen detection limits as low as 0.04 mg L(-1) have been measured with the coated optodes. The novel biofouling-resistant optosensors have been successfully validated against a commercial oxygen electrode and are shown to respond faster than the electrochemical device for large oxygen concentration changes. The biomimetic coatings will be particularly useful for drift-free long-term operation of environmental optosensors and in vivo fiber-optic oxygen analyzers.Keywords
This publication has 14 references indexed in Scilit:
- Characterization of implantable biosensor membrane biofoulingAnalytical and Bioanalytical Chemistry, 2000
- Peer Reviewed: Oxygen Sensors Based on Luminescence Quenching.Analytical Chemistry, 1999
- The early stages of marine biofouling and its effect on two types of optical sensorsEnvironment International, 1998
- Optochemical sensors in water monitoringPublished by Elsevier ,1998
- Fibre-optic chemical sensorsPublished by Elsevier ,1998
- Evaluation of ENDECO 1184C dissolved oxygen recorders for use in temperate estuariesWater Research, 1995
- Oxygen-sensitive layers for optical fibre devicesMicrochimica Acta, 1995
- Modelled diffusion-controlled response and recovery behaviour of a naked optical film sensor with a hyperbolic-type response to analyte concentrationThe Analyst, 1992
- Photophysics and oxygen quenching of transition-metal complexes on fumed silicaLangmuir, 1991
- Rate Constants for the Quenching of Excited States of Metal Complexes in Fluid SolutionJournal of Physical and Chemical Reference Data, 1989