Experience with a gastrointestinal marker (51CrCl3) in a combined study of ileal function using 75SeHCAT and 58CoB12 measured by whole body counting.
Open Access
- 30 September 1990
- Vol. 31 (10) , 1120-1125
- https://doi.org/10.1136/gut.31.10.1120
Abstract
Introduction of a radioactive gastrointestinal marker (51CrCl3) into a combined study (75SeHCAT + 58CoB12) of ileal function by whole body counting has been undertaken. The technique was assessed in 23 subjects (15 patients with inflammatory bowel disease, six on non-steroidal anti-inflammatory drugs for rheumatoid arthritis, and two normal subjects). Mean (SD) 51CrCl3 retention was only 4.1 (6.0)% on day 4, and was similar on day 7 in subjects given a second dose of 51CrCl3 on day 4. Only one subject had more than 20% of 51CrCl3 retention after four days. A 51CrCl3 correction method adequately corrected for colonic hold up of 58CoB12, when compared with final equilibrium values of 58CoB12 retention. Use of the non-absorbed 58CoB12 fraction as a gastrointestinal marker gave good agreement with the 51CrCl3 method in correcting 75SeHCAT values. In all subjects studied, corrections for colonic retention of 75SeHCAT on day 4, were small (less than 7% of dose) and did not affect the assessment of any subject. In conclusion, an additional gastrointestinal marker such as 51CrCl3 is unnecessary in our combined study since that role can be effected, when indicated by the non-absorbed 58CoB12 fraction.Keywords
This publication has 17 references indexed in Scilit:
- 75Se HCAT test in the detection of bile acid malabsorption in functional diarrhoea and its correlation with small bowel transit.Gut, 1987
- Critical analysis of the accuracy of a combined test ( 75 Se-HCAT and 58 Co-B 12 ) of ileal function using a whole-body counterClinical Physics and Physiological Measurement, 1987
- Is bile acid malabsorption underdiagnosed? An evaluation of accuracy of diagnosis by measurement of SeHCAT retention.BMJ, 1985
- The mechanism of diarrhoea resulting from pelvic and abdominal radiotherapy; a prospective study using selenium-75 labelled conjugated bile acid and cobalt-58 labelled cyanocobalaminThe British Journal of Radiology, 1984
- A comparison between the use of a shadow shield whole-body counter and an uncollimated gamma camera in the assessment of the seven-day retention of SeHCATThe British Journal of Radiology, 1984
- A PERSISTENT DEFECT IN INTESTINAL PERMEABILITY IN COELIAC DISEASE DEMONSTRATED BY A 51Cr-LABELLED EDTA ABSORPTION TESTThe Lancet, 1983
- SeHCAT Absorption: a Simple Test of Heal DysfunctionDigestion, 1983
- Assessment of ileal function by abdominal counting of the retention of a gamma emitting bile acid analogue.Gut, 1982
- Total body potassium calibrations for normal and obese subjects in two types of whole body counterPhysics in Medicine & Biology, 1979
- Measurement of gastrointestinal transit using radioactive chromiumGut, 1962