Preliminary Experiment with a Newly Developed Double Balloon, Double Lumen Catheter for Extracorporeal Life Support Vascular Access
- 1 September 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 49 (5) , 583-588
- https://doi.org/10.1097/01.mat.0000084105.01116.9e
Abstract
Recently, venovenous extracorporeal life support (VVECLS) using a double lumen catheter has been clinically used to avoid neurologic complications in the treatment of respiratory failure for neonates. However, recirculation, which is a limiting factor for oxygen delivery, still exists, and thus it does not contribute to oxygenation of the patient. We developed a newly designed double lumen catheter with a double balloon (DBDL) catheter for ECLS vascular access and performed two animal preliminary experiments in normal and hypoxic dog models (normal ventilation and one lung ventilation experiments) to investigate whether the DBDL catheter could prevent recirculation and maintain oxygen delivery to systemic circulation. The DBDL catheter (JCT Co., Hiroshima, Japan) of 15 Fr was fabricated from silicone. It consists of two lumens for drainage and return of blood with two balloons (distal and proximal balloons) that prevent oxygenated blood mixing with unoxygenated blood. VVECLS using a DBDL catheter was performed in 13 mongrel dogs (8 dogs for normal ventilation experiment weighing 12.9 ± 1.6 kg [mean ± SD], 5 dogs for one lung ventilation experiment weighing 16.6 ± 2.5 kg [mean ± SD]) under anesthesia in the two experiments. The bypass flow ranged from 10–40 ml/kg per minute in the normal ventilation experiment. VVECLS in the one lung ventilation experiment was performed with maximal bypass flow for 6 hours (ranged from 25.2 ± 8.0–28.3 ± 8.7 ml/kg per minute at balloon inflation and deflation). Recirculation and oxygen transfer of artificial lung with or without balloon inflation during VVECLS were studied. Recirculation decreased with balloon inflation at varied bypass flows during VVECLS in the normal ventilation experiment (varied from 1.5 ± 14.6–12.8 ± 16.7%) and for 6 hours after VVECLS initiation in the one lung ventilation experiment (varied from 12.2 ± 12.2–19.2 ± 6.5 %). In particular, the values at 3 and 6 hours were significantly lower than that of balloon deflation in the one lung ventilation experiment. The difference in O2 content between inlet and outlet in the artificial lung with balloon inflation was significantly higher than that of balloon deflation (varied from 3.7 ± 1.8–4.8 ± 1.9 ml/dl, p 2Keywords
This publication has 11 references indexed in Scilit:
- Recirculation in Double Lumen Catheter Veno-Venous Extracorporeal Membrane Oxygenation Measured by an Ultrasound Dilution TechniqueAsaio Journal, 2001
- Quantification of recirculation by thermodilution during venovenous extracorporeal membrane oxygenationJournal of Pediatric Surgery, 2000
- Extracorporeal Life SupportJAMA, 2000
- Modifying a venovenous extracorporeal membrane oxygenation circuit to reduce recirculationThe Annals of Thoracic Surgery, 2000
- Percutaneous access for venovenous extracorporeal life support in neonatesJournal of Pediatric Surgery, 1998
- Decreased incidence of intracranial hemorrhage using cephalic jugular venous drainage during neonatal extracorporeal membrane oxygenationJournal of Pediatric Surgery, 1993
- Multicenter comparison of conventional venoarterial access versus venovenous double-lumen catheter access in newborn infants undergoing extracorporeal membrane oxygenationJournal of Pediatric Surgery, 1993
- Venovenous Extracorporeal Life Support in Neonates Using a Double Lumen CatheterAnnual Northeast Bioengineering Conference, 1989
- Laboratory Evaluation of a Double Lumen Catheter for Venovenous Neonatal ECMOAnnual Northeast Bioengineering Conference, 1989
- Activated Coagulation Time of Whole BloodJAMA, 1966