Repaired RC Flat-Slab-Column Subassemblages under Lateral Loading
- 1 November 1995
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 121 (11) , 1710-1720
- https://doi.org/10.1061/(asce)0733-9445(1995)121:11(1710)
Abstract
Results of laboratory tests on four repaired reinforced-concrete flat-slab interior column connections, carrying quasi-static, reversed, horizontal loadings are presented. The specimens, which originally had totally failed, were repaired and subjected to gradually increasing reversed loading histories, similar to those imposed on the original specimens. A comparative analysis was made before the repair. The specimens were repaired by using externally screwed steel plates replacing the lost or damaged full reinforcement of the slab. In addition, high-pressure epoxy injection provided the bond between the concrete and the new reinforcement. Moreover, this repair method can be easily used to restore, strengthen, or upgrade existing and old flat-slab buildings, not suitably designed to withstand earthquakes. The practical aspects of the repair technique developed for postearthquake mass production were emphasized, with satisfactory results even when not applied by research laboratory experts.Keywords
This publication has 5 references indexed in Scilit:
- RC Flat Slab‐Column Subassemblages under Lateral LoadingJournal of Structural Engineering, 1993
- Strengthening of under-reinforced concrete beams with mechanically attached steel platesInternational Journal of Cement Composites and Lightweight Concrete, 1989
- Strength of Slab-Column Connections with Shear and Unbalanced FlexureJournal of the Structural Division, 1976
- Repaired R/C members under cyclic loadingEarthquake Engineering & Structural Dynamics, 1975
- The Shear Strength of Reinforced Concrete Members—SlabsJournal of the Structural Division, 1974