Determination of guidance levels of dose for diagnostic radiography in Taiwan
- 16 May 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (5) , 850-857
- https://doi.org/10.1118/1.1368126
Abstract
The International Atomic Energy Agency has recommended guidance levels of dose for diagnostic radiography for a typical adult patient. These levels were intended to act as thresholds to trigger investigations or corrective actions in ensuring optimized protection of patients and maintaining appropriate levels of good practice. Since guidance levels should be derived from wide scale surveys of exposure factors performed in individual hospitals, a national survey was conducted recently in Taiwan to collect these factors for the most frequent radiographic procedures. A total of 276 completed questionnaires were received and analyzed. In the questionnaire, respondents were asked to check those projections that were routinely performed in their department and to report machine data, patient data, output measurements, and technical factors including kVp, mAs, focus‐to‐film distance, table‐to‐film distance, aluminum filtration, and focal spot size. Based on the survey data, entrance skin exposures in air, i.e., free air exposures at the point of intersection of the x‐ray central beam with the entrance surface of the patient, were estimated using the RADCOMP program. Entrance surface doses to air and tissue with backscatter were then evaluated by the application of the exposure‐dose conversion factor and the backscatter factor obtained from TLD measurements and Monte Carlo simulations. Guidance levels were determined from survey results on the entrance surface dose based on optimization considerations involving the cost‐effectiveness analysis. Except for chest PA and LAT and skull LAT procedures, all guidance levels derived in this work are less than those recommended by the International Atomic Energy Agency. Survey data and guidance levels were provided to the national authorities to help them develop quality control and radiation protection programs for medical exposures.This publication has 8 references indexed in Scilit:
- Determination of Entrance Skin Doses and Organ Doses for Medical X Ray ExaminationsRadiation Protection Dosimetry, 1999
- An Estimation of the Genetically Significant Dose from Diagnostic Radiology for the South African Population, 1990–1991Health Physics, 1998
- Simulation of the Upper Gastrointestinal Fluoroscopic Examination for Calculation of Absorbed Dose in TissueHealth Physics, 1995
- Analyses of Radioactive Aerosols to Support Accurate Internal Dose Assessments at Chinshan Nuclear Power PlantHealth Physics, 1993
- Adult and Child Doses in Standardised X Ray ExaminationsRadiation Protection Dosimetry, 1992
- Population Dose Assessment from Radiodiagnosis in PortugalRadiation Protection Dosimetry, 1992
- Results of a Dosimetry Study in the European Community on Frequent X Ray Examination in InfantsRadiation Protection Dosimetry, 1992
- Effective Dose and Effective Dose Equivalent- The Impact of the New ICRP Definition For External Photon IrradiationHealth Physics, 1992