Effect of Sustained Load on Dispersion of Ventricular Repolarization and Conduction Time in the Isolated Intact Rabbit Heart
- 1 January 1996
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 7 (1) , 9-16
- https://doi.org/10.1111/j.1540-8167.1996.tb00455.x
Abstract
It is well known that myocardial stretch can elicit ventricular arrhythmias in experimental models. However, previous reports have predominantly documented stretch-induced arrhythmias during short, pulsatile stretch. The arrhythmogenic mechanism of sustained static stretch is incompletely understood.To examine the influence of sustained load on several electrophysiologic parameters, a latex balloon was placed into the left ventricle of ten isolated Langendorff-perfused rabbit hearts and filled with a neutral volume of fluid. The heart was paced from a catheter inside the right ventricle (apicoseptal endocardial position), and the following parameters were studied during steady-state pacing with a cycle length of 500 msec (S1) and during extrastimulation (S2, base drive of 8 beats): monophasic action potential (MAP) durations at 90% repolarization (APD90) from 5 to 6 epicardial electrodes located on both ventricles and one right ventricular endocardial contact electrode; dispersion of APD90 (range of MAP durations from all electrodes); effective refractory period (ERP) and longest activation time (pacing stimulus to MAP upstroke). After baseline recordings, the balloon inside the left ventricle was filled with a volume of 1.0 mL of fluid by means of a servo-controlled pump. The ERP was significantly shortened from 198 +/- 9 msec at baseline to 183 +/- 8 msec during sustained load (P < 0.03). Similarly, the average APD90 was shortened from 180 +/- 5 msec at baseline to 175 +/- 6 msec during sustained load (P < 0.006) with steady-state pacing and from 178 +/- 6 msec to 170 +/- 8 msec during premature extrastimulation (P < 0.03). At the same time, dispersion of APD90 was increased from 27 +/- 5 msec to 38 +/- 6 msec (P < 0.002) during steady-state pacing and from 28 +/- 4 msec to 38 +/- 6 msec (P = 0.013) during premature extrastimulation. The longest activation time among all MAP recordings was increased from 39 +/- 2 msec to 43 +/- 3 msec (P = 0.003) during steady-state pacing and from 56 +/- 6 msec to 69 +/- 6 msec during premature extrastimulation (P < 0.003).Sustained load shortens the ERP and the mean APD90, and at the same time increases dispersion of APD90 and prolongs activation times. These findings provide additional insight into the arrhythmogenic mechanisms of sustained mechanical load.Keywords
This publication has 34 references indexed in Scilit:
- Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias.Circulation, 1992
- Regional changes in ventricular excitability during load manipulation of the in situ pig heart.The Journal of Physiology, 1990
- Stretch-induced arrhythmias in the isolated canine ventricle. Evidence for the importance of mechanoelectrical feedback.Circulation, 1990
- Effect of acute volume load on refractoriness and arrhythmia development in isolated, chronically infarcted canine hearts.Circulation, 1989
- Congestive heart failure and arrhythmias: An overviewThe American Journal of Cardiology, 1986
- Determinants of prognosis in idiopathic dilated cardiomyopathy as determined by programmed electrical stimulationThe American Journal of Cardiology, 1985
- Ventricular arrhythmias in severe heart failure: Incidence, significance, and effectiveness of antiarrhythmic therapyAmerican Heart Journal, 1985
- Autoregulation of contractility in the myocardial cellPflügers Archiv - European Journal of Physiology, 1972
- Automatie-f rdernde Dehnungseffekte an Purkinje-F den, Papillarmuskeln und Vorhoftrabekeln von Rhesus-AffenPflügers Archiv - European Journal of Physiology, 1967
- Änderungen des Ruhepotentials und der Kabeleigenschaften von Purkinje-Fäden bei der DehnungPflügers Archiv - European Journal of Physiology, 1964