18-Fluorine Fluorodeoxyglucose Positron Emission Tomography for the Diagnosis of Infection in the Postoperative Spine
- 15 June 2003
- journal article
- diagnostics
- Published by Wolters Kluwer Health in Spine
- Vol. 28 (12) , 1314-1319
- https://doi.org/10.1097/01.brs.0000065483.07790.34
Abstract
Background. Using conventional imaging methods, including magnetic resonance imaging and labeled leukocyte scanning, the diagnosis of infection in the postoperative spine remains a diagnostic challenge. Recently, promising results have been reported using 18F-fluorodeoxyglucose positron emission tomography for various infectious problems. This study aimed to investigate the value of 18F-fluorodeoxyglucose positron emission tomography in patients suspected of having spinal infection after previous surgery of the spine. Methods. Fifty-seven consecutive patients with a history of previous spinal surgery were prospectively included between February 1999 and June 2001. 18F-fluorodeoxyglucose positron emission tomography was performed 60 to 90 minutes after injection of 370 MBq 18F-fluorodeoxyglucose. Images were scored visually and semiquantitatively by two blinded, independent, certified nuclear medicine physicians, experienced with positron emission tomography. Differences were assessed by consensus. Results were correlated with final diagnosis allowing calculation of sensitivity, specificity and accuracy. Receiver operating characteristic analysis was performed to find optimal cut-off values. Results. Fifteen patients had spinal infection. Using the most sensitive cut-off values sensitivity, specificity and accuracy were 100%, 81%, and 86%, respectively, for both visual and semiquantitative scoring. In the group without metallic implants (n = 27), false positives (n = 2) only occurred in the first 6 months after surgery. In the group with metallic implants (n = 30), false positives (n = 6) were not confined to recently operated patients. Conclusions. Overall accuracy was excellent (86%) with a negative predictive value of 100%. 18F-fluorodeoxyglucose positron emission tomography holds promise to become the standard imaging technique in this difficult patient population, as it is straightforward, provides a rapid result (2 hours) and because accurate alternatives are lacking.Keywords
This publication has 25 references indexed in Scilit:
- Promising Role of 18-F-Fluoro-D-Deoxyglucose Positron Emission Tomography in Clinical Infectious DiseasesEuropean Journal of Clinical Microbiology & Infectious Diseases, 2002
- High F-18 FDG Uptake in a Paraspinal TextilomaClinical Nuclear Medicine, 2002
- Chronic bacterial osteomyelitis: prospective comparison of 18F-FDG imaging with a dual-head coincidence camera and 111In-labelled autologous leucocyte scintigraphyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- 18-Fluorodeoxyglucose positron emission tomographic imaging in the detection and monitoring of infection and inflammationSeminars in Nuclear Medicine, 2002
- Do high glucose levels have differential effect on FDG uptake in inflammatory and malignant disorders?Nuclear Medicine Communications, 2001
- The Postsurgical Lumbosacral Spine: Magnetic Resonance Imaging Evaluation Following Intervertebral Disk Surgery, Surgical Decompression, Intervertebral Bony Fusion, and Spinal InstrumentationRadiologic Clinics of North America, 2001
- Benign causes of 18-FDG uptake on whole body imagingSeminars in Nuclear Medicine, 1998
- Chronic osteomyelitis: diagnosis with tech netium-99m-d,l-hexamethylpropylene amine oxime labelled leucocytesEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- A Histologic Study of Soft-Tissue Reactions to Spinal ImplantsSpine, 1994
- Erythrocyte Sedimentation Rate and C-reactive Protein Values in Patients with Total Hip ArthroplastyPublished by Wolters Kluwer Health ,1987