A method has been developed for delineating arsenic implanted n+p junctions in silicon by selective etching in 0.5% in and examination by transmission electron microscopy. This method is particularly applicable to shallow junction (≲ 0.1 μm) devices where conventional methods are no longer applicable. The n+ region is selectively etched, and delineation occurs at a depth corresponding to a concentration of .