How to Reach Optimal Creatinine Clearances in Automated Peritoneal Dialysis
Open Access
- 1 January 1996
- journal article
- research article
- Published by SAGE Publications in Peritoneal Dialysis International
- Vol. 16 (1_suppl) , 167-171
- https://doi.org/10.1177/089686089601601s31
Abstract
This paper summarizes the basis of prescription for automated peritoneal dialysis (APD) established during a French national conference on APD. Clinical results and literature data show that peritoneal clearances are closely determined by peritoneal permeability and hourly dialysate flow rate, independently of dwell time or number of cycles. With APD, peritoneal creatinine clearance increases according to the hourly dialysate flow rate to a maximum (plateau), then decreases because of the multiplication of the drain-fill times. The hourly dialysate flow giving the maximum peritoneal creatinine clearance is defined as the “maximal effective dialysate flow” (MEDF). MEDF is higher for high peritoneal permeabilities: MEDF is 1.8 and 4.2 L/hr with nocturnal tidal peritoneal dialysis (TPD) for a 4-hr creatinine dialysate-to-plasma ratio (DIP) of 0.50 and 0.80, respectively. With nightly intermittent peritoneal dialysis (NIPD), MEDF is 1.6 and 2.3 Llhr for a DIP of 0.50 and 0.78, respectively. Under these conditions, tidal modalities can only be considered as a way to increase the MEDF. Using the MEDF concept for an identical APD session duration, the maximal weekly normalized peritoneal creatinine clearance can vary by 340% when 4hr DIP varies from 0.41 to 0.78. APD is not recommended when 4-hr creatinine DIP is lower than 0.50. However, the limits of this technique may be reached at higher peritoneal permeabilities in anurics because of the duration of sessions andlor the additional exchanges required by these patients.Keywords
This publication has 8 references indexed in Scilit:
- Optimization of dialysate flow and mass transfer during automated peritoneal dialysisAmerican Journal of Kidney Diseases, 1995
- A Comparison of Clearances on Tidal Peritoneal Dialysis and Intermittent Peritoneal DialysisaPeritoneal Dialysis International, 1994
- Relationship between body size, fill volume, and mass transfer area coefficient in peritoneal dialysis.Journal of the American Society of Nephrology, 1994
- Automated peritoneal dialysisPublished by Springer Nature ,1994
- Techniques, Prescriptions, and IndicationsPublished by Springer Nature ,1993
- Weekly Clearances of Urea and Creatinine on CAPD and NIPDPeritoneal Dialysis International, 1992
- A quantitative description of solute and fluid transport during peritoneal dialysisKidney International, 1992
- The peritoneal transport of serum proteins and neutral dextran in CAPD patientsKidney International, 1989