Which electrode? A comparison of four endoscopic methods of electrocoagulation in experimental bleeding ulcers.
Open Access
- 1 December 1984
- Vol. 25 (12) , 1424-1431
- https://doi.org/10.1136/gut.25.12.1424
Abstract
Several inexpensive endoscopic methods of electrocoagulation have been advocated for treatment of gastrointestinal haemorrhage. We compared four types of electrode: dry monopolar - Cameron Miller (M), liquid monopolar - Storz (L), bipolar - Bicap ACMI (B), and heater probe - Seattle (H). The electrical and thermal properties of these probes were studied using computerised monitoring of energy deposition and their efficacy and safety was tested in a randomised study in 140 experimental canine gastric ulcers. At optimal pulse settings 20J (M), 70J (L), 17J (B), 15J (H), effective haemostasis was achieved in all ulcers, the mean number of pulses being M5, L6, H6 and B11, the first three requiring significantly (p less than 0.01) less pulse than B. Relative safety of the electrodes was assessed by comparing the incidence of full thickness damage at histology: B24%, H20%, L58% and M69%; B and H proving significantly (p less than 0.01) safer than L and M. Sticking was assessed as H greater than B greater than M much greater than L. Insensitivity to extreme angulation and force of application was assessed as L greater than B greater than M (H is preset). Of the two safer electrodes the heater probe was more effective than the bipolar probe. Despite its greater tendency to stick than the other devices, the heater probe appeared the most promising of the endoscopic electrodes tested.Keywords
This publication has 26 references indexed in Scilit:
- CONTROLLED TRIAL OF ARGON LASER PHOTOCOAGULATION IN BLEEDING PEPTIC ULCERSThe Lancet, 1981
- Randomised trial of endoscopic argon laser photocoagulation in bleeding peptic ulcers.Gut, 1981
- Surgical diathermy – A reviewJournal of Medical Engineering & Technology, 1981
- Endoscopic Electrocoagulation - An Alternative to Operative Hemostasis in Active Gastroduodenal Bleeding?Endoscopy, 1980
- The Healing Process of Experimentally Produced Bleeding Lesions after Hemostatic Electrocoagulation with Simultaneous Instillation of WaterEndoscopy, 1980
- The multisection tissue slicer: A simpler technique for assessing the maximal depth of experimental injuryGastrointestinal Endoscopy, 1979
- Endoscopic electrohemostasis of active upper gastrointestinal bleedingThe American Journal of Surgery, 1979
- Eine neue Methode zur endoskopischen Hochfrequenzkoagulation von Schleimhautdefekten - A new method for the endoscopic coagulation of mucous membrane lesions using high frequency electric currentsBiomedizinische Technik/Biomedical Engineering, 1978
- Experimental electrocoagulation of dog gastric mucosaGastrointestinal Endoscopy, 1975
- Electrocoagulation of Bleeding in the Upper Part of the Gastrointestinal TractArchives of Surgery, 1975