Extensive Coagulation Monitoring in Patients After Implantation of the MicroMed Debakey Continuous Flow Axial Pump
- 1 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 50 (5) , 424-431
- https://doi.org/10.1097/01.mat.0000136515.97686.a2
Abstract
Ventricular assist device (VAD) implantation is associated with impaired primary hemostasis and thromboembolic complications. Recently, a new generation of implantable continuous flow axial pumps was introduced into clinical application. To study the potential thrombogenic properties of this type of pump, we applied extensive platelet monitoring was applied. In our institution, 13 patients received the MicroMed DeBakey VAD as a bridge to transplantation. Routine coagulation tests (platelet count, activated partial thromboplastin time, prothrombin time, antithrombin III activity) and platelet function tests (whole blood aggregometry, thrombelastography, flow cytometry) were performed. No clinically relevant thromboembolic events were detected. No correlation was found between global function tests, platelet aggregation, and thrombelastography. No correlation was detected between platelet activation and hemolysis parameters. Platelet aggregation and coagulation index were significantly suppressed early after operation. A subsequent phase of hyper-aggregability, starting around day 6, suggested the initiation of antiaggregation therapy. Platelet activation markers were upregulated in the postoperative period but were returned to preoperative levels after initiation of aspirin. In contrast to routine coagulation monitoring, platelet function tests reflect in detail the coagulation status of blood pump recipients and the efficiency of antiaggregation therapy. Aspirin and dipyridamole therapy in addition to oral anticoagulation using phenprocoumon may contribute to platelet function and clot mechanics restoration and is, therefore, recommended for patients after VAD implantation.Keywords
This publication has 26 references indexed in Scilit:
- Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular functionThe Journal of Heart and Lung Transplantation, 2002
- Inflammatory Response after Implantation of a Left Ventricular Assist Device: Comparison between the Axial Flow MicroMed DeBakey VAD and the Pulsatile Novacor DeviceAsaio Journal, 2001
- Alterations in coagulation after implantation of a pulsatile Novacor LVAD and the axial flow micromed DeBakey LVADThe Annals of Thoracic Surgery, 2000
- Prevalence and Persistence of Heparin/Platelet Factor 4 Antibodies in Patients with Heparin Coated and Noncoated Ventricular Assist DevicesAsaio Journal, 2000
- Platelet morphology in patients with mechanical circulatory supportEuropean Journal of Cardio-Thoracic Surgery, 1997
- Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devicesThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Pathophysiologic Role of Contact Activation in Bleeding Followed by Thromboembolic Complications After Implantation of a Ventricular Assist DeviceAsaio Journal, 1995
- Platelet function, thrombin and fibrinolytic activity in patients with heart failureEuropean Heart Journal, 1993
- Ventricular assist devices and total artificial hearts: A combined registry experienceThe Annals of Thoracic Surgery, 1993