Producing STR Locus Patterns from Bloodstains and Other Forensic Samples Using an Infrared Fluorescent Automated DNA Sequencer
- 1 May 1996
- journal article
- research article
- Published by ASTM International in Journal of Forensic Sciences
- Vol. 41 (3) , 418-424
- https://doi.org/10.1520/jfs13927j
Abstract
Short tandem repeat (STR) analysis is increasingly being used in forensic case analysis because of the large number of STR loci in the human genome and their highly polymorphic nature. An automated DNA sequencer using high sensitivity infrared (IR) fluorescence technology was used to detect STR allele patterns from simulated forensic samples. The amplification strategy used a 19 base pair extension on the 5′ end of one of the PCR primers. This sequence is identical to the sequence of a universal M13 Forward sequencing primer which is included in the amplification reaction. Allelic bands were detected by incorporation of the M13 primer-fluorescent dye conjugate into PCR products thus eliminating the need for direct conjugation of fluorescent dye to individual STR primers. By using an IR-based automated DNA sequencer and Tth DNA polymerase, polymorphic STR alleles were detected on-line rapidly and efficiently from bloodstains using only a high temperature incubation to extract DNA from blood cells. Five STR loci were also amplified using Chelex extracted DNA from simulated forensic samples. Multiplexing of three primer pairs in a single PCR mixture for amplification was accomplished using Taq polymerase. This system combines IR fluorescence chemistry and laser technology thus eliminating the need for radioactivity and the gel handling required with silver staining and fluor detection systems. Real-time detection permits immediate visualization of the data and STR alleles are displayed as familiar autoradiogramlike images that can be analyzed by computer. By loading a 64 lane gel twice and multiplexing with three primer pairs, forensic scientists can type at least three loci from 120 samples in one day.Keywords
This publication has 14 references indexed in Scilit:
- A New Method for the Synthesis of Heptamethine Cyanine Dyes: Synthesis of New Near-Infrared Fluorescent LabelsThe Journal of Organic Chemistry, 1995
- Evaluation of an automated DNA profiling system employing multiplex amplification of four tetrameric STR lociInternational journal of legal medicine, 1994
- Variation in Short Tandem Repeat sequences ?a survey of twelve microsatellite loci for use as forensic identification markersInternational journal of legal medicine, 1994
- Automated DNA profiling by fluorescent labeling of PCR products.Genome Research, 1992
- Survey of human and rat microsatellitesGenomics, 1992
- Genetic variation at five trimeric and tetrameric tandem repeat loci in four human population groupsGenomics, 1992
- Continuous, on‐line DNA sequencing using a versatile infrared laser scanner/electrophoresis apparatusElectrophoresis, 1992
- Near-Infrared Fluorogenic Labels: New Approach to an Old ProblemAnalytical Chemistry, 1991
- A discussion of the robustness of methods for assessing the evidential value of DNA single locus profiles in crime investigationsElectrophoresis, 1991
- Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA PolymeraseScience, 1988