An information fusion framework for robust shape tracking
- 17 January 2005
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 27 (1) , 115-129
- https://doi.org/10.1109/tpami.2005.3
Abstract
Existing methods for incorporating subspace model constraints in shape tracking use only partial information from the measurements and model distribution. We propose a unified framework for robust shape tracking, optimally fusing heteroscedastic uncertainties or noise from measurement, system dynamics, and a subspace model. The resulting nonorthogonal subspace projection and fusion are natural extensions of the traditional model constraint using orthogonal projection. We present two motion measurement algorithms and introduce alternative solutions for measurement uncertainty estimation. We build shape models offline from training data and exploit information from the ground truth initialization online through a strong model adaptation. Our framework is applied for tracking in echocardiograms where the motion estimation errors are heteroscedastic in nature, each heart has a distinct shape, and the relative motions of epicardial and endocardial borders reveal crucial diagnostic features. The proposed method significantly outperforms the existing shape-space-constrained tracking algorithm. Due to the complete treatment of heteroscedastic uncertainties, the strong model adaptation, and the coupled tracking of double-contours, robust performance is observed even on the most challenging cases.Keywords
This publication has 39 references indexed in Scilit:
- Coupled-Contour Tracking through Non-orthogonal Projections and Fusion for EchocardiographyPublished by Springer Nature ,2004
- Component Fusion for Face Detection in the Presence of Heteroscedastic NoisePublished by Springer Nature ,2003
- Cortex segmentation: a fast variational geometric approachIEEE Transactions on Medical Imaging, 2002
- A shape-space-based approach to tracking myocardial borders and quantifying regional left-ventricular function applied in echocardiographyIEEE Transactions on Medical Imaging, 2002
- Merging and splitting eigenspace modelsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2000
- Multi-frame optical flow estimation using subspace constraintsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1999
- Image-flow computation: An estimation-theoretic framework and a unified perspectiveCVGIP: Image Understanding, 1992
- Determining optical flowArtificial Intelligence, 1981
- Robust StatisticsPublished by Wiley ,1981
- Ridge Regression: Biased Estimation for Nonorthogonal ProblemsTechnometrics, 1970