Measurement of Oil Film Thickness Between W-N Helical Gear Tooth Profiles Using Laser Transmission Method

Abstract
In this experiment, it was the first time that the center oil film thickness between W-N helical gear tooth profiles has been measured indirectly through measuring the change of gaps of a pair of unloaded involute spur gears mounted on the extended shafts of W-N gear box by means of laser transmission method. During the measurement of every time, it was calibrated separately, so that all errors could be eliminated completely except ones of measuring apparatus. The accuracy of this method has reached 0.1 μm (dynamic) and 0.01 μm (static), respectively. Measurement results were identical with theoretical ones. This method is also suitable for the measurement of center oil film thickness between tooth profiles and deformation of any cylindrical spur and helical gears.

This publication has 0 references indexed in Scilit: