Superior displacement of the hip in total joint replacement: Effects of prosthetic neck length, neck‐stem angle, and anteversion angle on the moment‐generating capacity of the muscles
- 1 November 1994
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 12 (6) , 860-870
- https://doi.org/10.1002/jor.1100120614
Abstract
The purpose of this study was to determine the effects of superior displacement of the hip center and changes in three prosthetic parameters (neck length, neck‐stem angle, and anteversion angle) on the capacity of muscles to generate force and moment about the hip. A three‐dimensional model that calculates the maximum isometric forces and moments generated by 25 muscles crossing the hip over a wide range of body positions was used to evaluate the effects of a 2 cm elevation of the hip center and changes in the prosthetic parameters. After superior displacement of the hip center, the neck length was increased from 0 to 3 cm, the neck‐stem angle was varied between 110 and 150°, and the anteversion angle was varied between 0 and 40°. Our analysis showed that a 2 cm superior displacement of the hip center would decrease the moment‐generating capacity of the four muscle groups studied (abductors, adductors, flexors, and extensors) if neck length were not increased to compensate for decreased muscle length. In the computer model of an adult man that we used, a 2 cm increase in neck length restored the moment‐generating capacity of the muscles by increasing muscle length and force‐generating capacity. However, a 3 cm increase in neck length increased passive muscle forces substantially, which potentially could limit joint motion. An increased neck‐stem angle (i.e., a valgus neck) decreased the abduction moment arm but increased the moment‐generating capacity of the other muscle groups. A change in the anteversion angle from 0 to 40° had a relatively small effect on the isometric moment‐generating capacity of the muscles studied.Keywords
This publication has 42 references indexed in Scilit:
- Effects of hip center location on the moment-generating capacity of the musclesJournal of Biomechanics, 1993
- Femoral Head Autografting With Total Hip Arthroplasty for Lateral Acetabular DysplasiaPublished by Wolters Kluwer Health ,1990
- Acetabular Augmentation in Primary and Revision Total Hip Arthroplasty With Cementless ProsthesesPublished by Wolters Kluwer Health ,1990
- Muscle fiber architecture in the human lower limbJournal of Biomechanics, 1990
- Quantitative Measurements of Hip Strength in Different Age GroupsPublished by Wolters Kluwer Health ,1989
- The influence of chair height on lower limb mechanics during risingJournal of Orthopaedic Research, 1989
- Arthroplasty for congenital hip dislocation Techniques for acetabular reconstructionActa Orthopaedica, 1989
- An integrated biomechanical analysis of normal stair ascent and descentJournal of Biomechanics, 1988
- The sensitivity of muscle force predictions to changes in physiologic cross-sectional areaJournal of Biomechanics, 1986
- Abductor Muscle Performance in Total Hip Arthroplasty with and Without Trochanteric OsteotomyPublished by Wolters Kluwer Health ,1985