Time‐of‐flight quantitative measurements of blood flow in mouse hindlimbs
- 29 March 2004
- journal article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 468-474
- https://doi.org/10.1002/jmri.20025
Abstract
Purpose To evaluate the feasibility of using time‐of‐flight (TOF) imaging to directly measure hindlimb blood flow in a mouse model of peripheral vascular disease. Materials and Methods Four tubes were imaged simultaneously (diameters = 0.39 mm, 0.59 mm, and two at 1.46 mm) with a 1.0 mM copper sulfate solution for 19 flow velocities. In vivo measurements were performed in the hindlimbs of three mouse strains—C57BL/6 (N= 5), BALB/c (N = 5), and 129S2/Sv (N = 5)—three weeks after femoral artery ligation with a calibration standard. Results The flow phantom showed that the intensity was linear (r2 = 0.92) over the pertinent blood flow velocities in the mouse hindlimbs. Measurements of the blood flow in the distal hindlimbs in different strains of mice (combination of both the venous and arterial flows) were obtained 21 days after right‐sided femoral artery occlusion. The results showed that under similar conditions of anesthesia and temperature, SV129 mice on the nonligated side had the highest flows (0.50 ± 0.07 mL/minute), followed by C57BL/6 (0.28 ± 0.04 mL/minute) and BALB/c (0.23 ± 0.05 mL/minute), P < 0.02. The ligated side measurements (SV129, 0.31 ± 0.05 mL/minute (P = 0.02); C57BL/6, 0.21 ± 0.02 mL/minute (P = 0.13); and BALB/c, 0.12 ± 0.02 mL/minute (P= 0.06)) showed a trend in BALB/c and C57BL/6 and significant differences in SV129 for incomplete recovery three weeks after surgery, compared to the nonligated side. Conclusion Two‐dimensional TOF imaging permits quantitative in vivo measurements of hindlimb blood flow in a mouse model of peripheral vascular disease without the need of contrast injection, offering advantages of serial imaging not limited by tissue penetration. J. Magn. Reson. Imaging 2004;19:468–474.Keywords
This publication has 24 references indexed in Scilit:
- Quantitative regional blood volume studies in rat myocardium in VivoMagnetic Resonance in Medicine, 1998
- A Birdcage Coil Tuned by RF Shielding for Application at 9.4 TJournal of Magnetic Resonance, 1998
- Artifacts and signal loss due to flow in the presence of Bo inhomogeneityMagnetic Resonance in Medicine, 1996
- MR imaging of flow through tortuous vessels: A numerical simulationMagnetic Resonance in Medicine, 1994
- Time of flight quantification of coronary flow with echo-planar MRIMagnetic Resonance in Medicine, 1993
- Time‐of‐flight effects in MR imaging of flowMagnetic Resonance in Medicine, 1990
- Blood flow to different rat skeletal muscle fiber type sections during isometric contractions in situMedicine & Science in Sports & Exercise, 1988
- A mathematical model for signal from spins flowing during the application of spin echo pulse sequencesMagnetic Resonance Imaging, 1988
- Determination of Flow Velocities from Magnetic Resonance Multiple Spin-Echo ImagesActa Radiologica, 1987
- ECG-triggered arterial FLASH-MR flow measurement using an external standardMagnetic Resonance Imaging, 1987