A Comparison of the INVOS 4100 and the NIRO 300 Near-Infrared Spectrophotometers
- 1 March 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 94 (3) , 586-590
- https://doi.org/10.1097/00000539-200203000-00020
Abstract
We determined whether two different devices for measuring near-infrared spectroscopy (NIRS)—the INVOS 4100 and the NIRO 300—produce similar cerebral oxygenation data during the CO2 challenge test. Nineteen patients anesthetized with sevoflurane, 67% nitrous oxide in oxygen, and fentanyl were studied. A series of measurements of regional cerebral oxygen saturation (rSo2), measured by the INVOS 4100, and tissue oxygen index (TOI), measured by the NIRO 300, were performed in the following conditions: 1) normocapnia (Paco2, 35–45 mm Hg); 2) hypocapnia (Paco2, 25–35 mm Hg); 3) normocapnia; and 4) hypercapnia (Paco2, 45–55 mm Hg). Hemodynamic variables, including arterial blood gases and cerebral blood flow velocity, were measured at the same time with transcranial Doppler. The values and percentage changes of rSo2 and TOI were compared by using regression analysis and Bland and Altman analysis. The rSo2 showed a significant positive correlation with TOI (r = 0.58, P < 0.01). The percentage change of rSo2 also showed a significant positive correlation with the percentage change of TOI during the CO2 challenge (r = 0.85, P < 0.01). Bland and Altman analysis revealed a bias of −0.5% with 2 sd of 15.6% when comparing the rSo2 value with the TOI value, and it showed a bias of −3.4% with 2 sd of 15.2% when comparing the percentage change of rSo2 with the percentage change of TOI, indicating unacceptable disagreement of these data. These results indicate that cerebral oxygen saturation and its relative change during the CO2 challenge may vary depending on the type of NIRS used. Because the measurement technique and algorithm were different in each device, we should carefully consider the clinical application of the values produced by NIRS.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of two commercially available near-infrared spectroscopy instruments for cerebral oximetryJournal of Neurosurgery, 2000
- A comparison of the monitors INVOS 3100 and NIRO 500 in detecting changes in cerebral oxygenationActa Anaesthesiologica Scandinavica, 1999
- A Comparison of the Hamamatsu NIRO 500 and the INVOS 3100 Near-Infrared SpectrophotometersAnaesthesia and Intensive Care, 1998
- Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomyJournal of Neurosurgery, 1998
- Near-Infrared spectroscopy: Theory and applicationsJournal of Cardiothoracic and Vascular Anesthesia, 1996
- Near-infrared spectroscopy in adults: effects of extracranial ischaemia and intracranial hypoxia on estimation of cerebral oxygenationBritish Journal of Anaesthesia, 1994
- Near infrared spectroscopy in adultsAnaesthesia, 1993
- Measurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn InfantsDevelopmental Neuroscience, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Noninvasive, Infrared Monitoring of Cerebral and Myocardial Oxygen Sufficiency and Circulatory ParametersScience, 1977