Initial stability of a new hybrid fixation hip stem: Experimental measurement of implant-bone micromotion under torsional load in comparison with cemented and cementless stems
- 7 April 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 50 (4) , 605-615
- https://doi.org/10.1002/(sici)1097-4636(20000615)50:4<605::aid-jbm17>3.0.co;2-p
Abstract
A new hybrid fixation stem, named cemented–locked uncemented (CLU), for total hip arthroplasty was developed to achieve good initial stability. Primary stability is guaranteed by the cement which is injected into two pockets in the lateral area. This leaves a large surface available for long‐term biologic fixation (direct bone attachment on implant). This study evaluates in vitro the initial stability of the CLU prototype under torsional load, in comparison with cemented and cementless stems. The results show that the CLU stem is very stable in simulated stair climbing. Its micromotions are comparable to those of a cemented prosthesis, and significantly less (80–90% lower) than those for a cementless stem. These findings confirm the optimal initial stability expected from the CLU prototype. This new design, which employs hybrid fixation, should improve bone formation on the implant and reduce the risk of stem loosening. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res, 50, 605–615, 2000.Keywords
This publication has 35 references indexed in Scilit:
- Analysis of cementless implants using interface nonlinear friction—Experimental and finite element studiesJournal of Biomechanics, 1997
- A Critical Analysis of Stress Shielding Evaluation of Hip ProsthesesPublished by Begell House ,1997
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- Coulomb frictional interfaces in modeling cemented total hip replacements: A more realistic modelJournal of Biomechanics, 1995
- Frictional interface micromotions and anisotropic stress distribution in a femoral total hip componentJournal of Biomechanics, 1993
- Effects of femoral component material properties on cementless fixation in total hip arthroplasty: A comparison study between carbon composite, titanium alloy, and stainless steelThe Journal of Arthroplasty, 1993
- Telemeterized in vivo hip joint force data: A report on two patients after total hip surgeryJournal of Orthopaedic Research, 1991
- Biomechanical and Histologic Investigation of Cemented Total Hip ArthroplastiesClinical Orthopaedics and Related Research, 1989
- Examination of Rotational Fixation of the Femoral Component in Total Hip ArthroplastyPublished by Wolters Kluwer Health ,1989
- Strains and micromotions of press-fit femoral stem prosthesesJournal of Biomechanics, 1987