Validation of transit-time flowmetry for chronic measurements of regional blood flow in resting and exercising rats.
Open Access
- 1 July 1997
- journal article
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 30 (7) , 897-908
- https://doi.org/10.1590/s0100-879x1997000700013
Abstract
The objective of the present study was to validate the transit-time technique for long-term measurements of iliac and renal blood flow in rats. Flow measured with ultrasonic probes was confirmed ex vivo using excised arteries perfused at varying flow rates. An implanted 1-mm probe reproduced with accuracy different patterns of flow relative to pressure in freely moving rats and accurately quantitated the resting iliac flow value (on average 10.43 +/- 0.99 ml/min or 2.78 +/- 0.3 ml min-1 100 g body weight-1). The measurements were stable over an experimental period of one week but were affected by probe size (resting flows were underestimated by 57% with a 2-mm probe when compared with a 1-mm probe) and by anesthesia (in the same rats, iliac flow was reduced by 50-60% when compared to the conscious state). Instantaneous changes of iliac and renal flow during exercise and recovery were accurately measured by the transit-time technique. Iliac flow increased instantaneously at the beginning of mild exercise (from 12.03 +/- 1.06 to 25.55 +/- 3.89 ml/min at 15 s) and showed a smaller increase when exercise intensity increased further, reaching a plateau of 38.43 +/- 1.92 ml/min at the 4th min of moderate exercise intensity. In contrast, exercise-induced reduction of renal flow was smaller and slower, with 18% and 25% decreases at mild and moderate exercise intensities. Our data indicate that transit-time flowmetry is a reliable method for long-term and continuous measurements of regional blood flow at rest and can be used to quantitate the dynamic flow changes that characterize exercise and recovery.Keywords
This publication has 18 references indexed in Scilit:
- Different Flow Regulation Mechanisms Between Celiac and Mesenteric Vascular Beds in Conscious RatsHypertension, 1995
- In vivo validation of a transit-time ultrasonic volume flow meterJournal of Pharmacological and Toxicological Methods, 1994
- Cardiovascular effects of neuronal activation of the extended amygdala in ratsBrain Research, 1993
- Nitric oxide‐dependent and ‐independent hyperaemia due to calcitonin gene‐related peptide in the rat stomachBritish Journal of Pharmacology, 1993
- Simultaneous assessment of cardiac output with pulsed Doppler and electromagnetic flowmeters during cardiac stimulationJournal of Pharmacological and Toxicological Methods, 1993
- Differential Hemodynamic Responses to Selective Inhibitors of Cyclic Nucleotide Phosphodiesterases in Conscious RatsJournal of Cardiovascular Pharmacology, 1992
- Measuring Bovine Mammary Gland Blood Flow Using a Transit Time Ultrasonic Flow ProbeJournal of Dairy Science, 1989
- Effect of perivascular electromagnetic flow probes on pulmonary hemodynamicsJournal of Applied Physiology, 1988
- Regional blood flow in conscious spontaneously hypertensive rats.The Japanese Journal of Physiology, 1983
- An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.Journal of Applied Physiology, 1974