Stop-Flow Programmable Selectivity with a Dual-Column Ensemble of Microfabricated Etched Silicon Columns and Air as Carrier Gas
- 8 March 2005
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (7) , 2078-2084
- https://doi.org/10.1021/ac040174p
Abstract
A series-coupled ensemble of microfabricated GC columns made by dry reactive ion etching of silicon substrates is evaluated for use with pneumatic selectivity enhancement techniques for targeted pairs of volatile organic compounds. Each column is 3.0 m long with a 150 miceom wide by 240 microm deep cross section. Dynamic coating was used to prepare a nonpolar column with a dimethyl polysiloxane stationary phase and a moderately polar column with a trifluoropropylmethyl polysiloxane stationary phase. Each column generates 5000-6000 theoretical plates. The columns are operated in series with the nonpolar column connected to a split inlet, the polar column connected to a flame ionization detector, and a valve connected between the column junction point and the inlet to the first column. When the valve is closed, the effluent from the first column passes directly into the second column. When the valve is open, both ends of the first column are at the inlet pressure, and flow stops in this column while increased flow is obtained in the second column. For analyte pairs that are separated by the first column but coelute from the column ensemble, the valve is opened for a few seconds after the first component of the pair has passed into the second column but the second component is still in the first column. The result is enhanced separation of the pair in the ensemble chromatogram. Relatively thick cross-linked stationary-phase films are used to increase retention for volatile compounds. The combination of air carrier gas and stationary-phase film thickness in the range 1-2 microm requires the use of relatively low average carrier gas velocities (typically less than 10 cm/s) for adequate resolving power of the column ensemble. Selectivity enhancement under isothermal conditions for a 14-component mixture of volatile organic compounds is demonstrated where neither of the columns alone nor the column ensemble without selectivity enhancement could obtain a complete separation.Keywords
This publication has 23 references indexed in Scilit:
- Dynamic solid phase microextraction for sampling of airborne sarin with gas chromatography-mass spectrometry for rapid field detection and quantificationJournal of Separation Science, 2004
- Integration test of a miniature ExB mass spectrometer with a gas chromatograph for development of a low-cost, portable, chemical-detection systemTrAC Trends in Analytical Chemistry, 2004
- Two high-speed, portable GC systems designed for the measurement of non-methane hydrocarbons and PAN: Results from the Jungfraujoch High Altitude ObservatoryPublished by Royal Society of Chemistry (RSC) ,2004
- Parylene gas chromatographic column for rapid thermal cyclingJournal of Microelectromechanical Systems, 2002
- Membrane and trap system for continuous monitoring of volatile organic compounds using a portable gas chromatograph with thermal conductivity detectorJournal of Separation Science, 2002
- Fast GC instrumentation and analysis for field applicationsField Analytical Chemistry & Technology, 2001
- High-Speed Analysis of Complex Indoor VOC Mixtures by Vacuum-Outlet GC with Air Carrier Gas and Programmable RetentionEnvironmental Science & Technology, 2000
- Development of membrane extraction with a sorbent interface–micro gas chromatography system for field analysisJournal of Chromatography A, 2000
- High-Speed, Vacuum-Outlet GC Using Atmospheric-Pressure Air as Carrier GasAnalytical Chemistry, 1999
- Review and summary of a silicon micromachined gas chromatography systemIEEE Transactions on Components, Packaging, and Manufacturing Technology: Part B, 1998