Demonstration of the Normal Extrahepatic Biliary Tract with Computed Tomography
- 1 February 1980
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 4 (1) , 48-52
- https://doi.org/10.1097/00004728-198002000-00009
Abstract
When optimum computed tomography (CT) technique and computed angiotomography are utilized, the normal extrahepatic biliary ducts (equal to or less than 6 mm in diameter in patients without cholecystectomy) can be demonstrated in .apprx. 30% of clinical scans. Measurement of the anteroposterior diameter of the bile duct is more accurate than recording the transverse diameter, since the apparent transverse dimension varies depending on the orientation of the duct in the plane of section. Phantom studies indicate that the absolute error of measurement is approximately 1 pixel diameter irrespective of duct diameter. The normal and abnormally dilated extrahepatic biliary ducts should be distinguished with CT.This publication has 2 references indexed in Scilit: