We present measurements of the x-ray focusing properties of square-pore microchannel plates (MCP’s). Square-pore MCP’s contain large numbers of closely packed optical surfaces, as required for grazing incidence x-ray optics. The surface of individual MCP channels has been measured and found to have high microroughness transverse to the channel axis and low microroughness parallel to the axis. The high frequency transverse roughness, on length scales greater than 400 nm, has a rms value of 5.9 nm and a Gaussian autocorrelation function with correlation length of 1.41 μm. We find that the geometric misalignments of the surfaces of different channels limit the angular resolution obtainable with current samples of MCP’s to 7.1 arcmin.Keywords
This publication has 3 references indexed in Scilit:
- X-ray focusing using square channel-capillary arraysReview of Scientific Instruments, 1991
- On the concentration, focusing, and collimation of x-rays and neutrons using microchannel plates and configurations of holesReview of Scientific Instruments, 1989
- Microchannel plate detectorsNuclear Instruments and Methods, 1979