Effects of graded reaming on fracture healing: Blood flow and healing studied in rat femurs
- 1 January 1994
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 65 (1) , 32-36
- https://doi.org/10.3109/17453679408993714
Abstract
In 30 rats, closed bilateral fractures of the femur were produced. On the left side intramedullary reaming was performed to 1.6 mm, and the fracture fixed with a steel pin with a diameter of 1.6 mm. On the right side the femoral canal was reamed to 2.0 mm and a hollow steel tube with a diameter of 2.0 mm was used for fixation. An additional 8 rats were used to obtain mechanical, dimensional and flow data on intact femurs, and another 10 rats were used to study the acute flow changes caused by fracture and different degrees of reaming and fracture. Fracture and reaming reduced total bone and cortical bone blood flows to about one third of normal flow, with no differences between the 1.6-mm and the 2.0-mm reamed bones. At 4 weeks, total bone flow was about double and cortical bone flow about 4 times increased in the 1.6-mm group. In the 2.0-mm reamed bones increases of approximately 5 times in total bone flow and of about 7 times in cortical flow were found. Callus flow was about twice the size of the respective cortical flow in both groups. Both total and cortical flows gradually subsided, without differences between the 2 groups. At 12 weeks, the callus area in the 2.0-mm group was greater than in the 1.6-mm group, while bone dimensions were greater in the 2.0-mm group at 4 and 12 weeks. Bending moment and rigidity were greater in the 1.6-mm group than in the 2.0-mm one at every time interval; no differences were found in fracture energy. We conclude that, in terms of healing, modest reaming is preferable to extensive reaming. The adverse effect of extensive reaming is not due to excessive flow derangement at the acute stage or to impaired vascularity at the phase of remodeling.Keywords
This publication has 18 references indexed in Scilit:
- Effects of intramedullary reaming and nailing of rat femur: A mechanical and chemical studyActa Orthopaedica, 1991
- Effect of fracture fixation on cortical bone blood flowJournal of Orthopaedic Research, 1990
- Effects of medullary reaming on fracture healing: Tibial osteotomies in rabbitsActa Orthopaedica, 1990
- Current Concepts of Fracture HealingClinical Orthopaedics and Related Research, 1989
- The cartilaginous fracture callus in ratsActa Orthopaedica, 1987
- The Effects of Reaming and Intramedullary Nailing on Fracture HealingPublished by Wolters Kluwer Health ,1986
- Effects of rotational instability on healing of femoral osteotomies in the ratActa Orthopaedica, 1984
- Effect of Instability on Experimental Fracture HealingActa Orthopaedica, 1982
- Methods for Testing the Mechanical Properties of the Rat FemurActa Orthopaedica, 1978
- Blood Supply and the Rate of Healing of Tibial FracturesClinical Orthopaedics and Related Research, 1974