Determination of bone mineral density by dual X‐ray absorptiometry in patients with uncemented total hip arthroplasty
- 1 November 1992
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 10 (6) , 836-844
- https://doi.org/10.1002/jor.1100100613
Abstract
Bone remodeling is an expected sequela with total hip arthroplasty (THA). Although there are several methods of estimating bone response in THA patients from radiographs, there are no accurate and generally accepted methods for quantitative determinations in vivo. In this study, we describe an application of dual x-ray absorptiometry (DXA) for measuring bone mineral content and bone mineral density in the proximal femur following THA. DXA is a noninvasive technique with minimal radiation exposure (<5 mrem). Various aspects of measurement error (accuracy and reliability) of this application of DXA were determined in a series of studies reported here. Accuracy error (how similar are the measured and actual values) was <1% determined in bone phantoms of four densities. Precision error (how reproducible are the measurements) was also <1% at all four densities in the phantoms and was only slightly elevated (0.9-1.5%) in repeated measurements of implanted cadaver femora. Precision error in vivo, determined both from multiple replicates on five patients and from duplicate scans on 30 patients, was further elevated but remained 5%) not previously measurable.Keywords
This publication has 26 references indexed in Scilit:
- Calibration of dual-energy X-ray absorptiometry for bone densityJournal of Bone and Mineral Research, 1991
- The effects of local versus average baseline determination on spinal densityCalcified Tissue International, 1991
- Computer predictions of bone remodeling around porous-coated implantsThe Journal of Arthroplasty, 1990
- The Anthropometric Total Hip Femoral ProsthesisPublished by Wolters Kluwer Health ,1989
- Bone QualityClinical Orthopaedics and Related Research, 1989
- Early Temporary Porosis of Bone Induced by Internal Fixation Implants A Reaction to Necrosis, Not to Stress Protection?Published by Wolters Kluwer Health ,1988
- Effects of ingrowth, geometry, and material on stress transfer under porous‐coated hip surface replacementsJournal of Orthopaedic Research, 1988
- Radiographic Criteria for the Clinical Performance of Uncemented Total Joint ReplacementsPublished by ASTM International ,1987
- Adaptive bone-remodeling theory applied to prosthetic-design analysisJournal of Biomechanics, 1987
- The Pulmonary Effects of Toxic Gases and SmokesThe British Journal of Radiology, 1950