Effect of two methods of hand heating on body temperature, forearm blood flow, and deep venous oxygen saturation
- 1 November 1990
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Endocrinology and Metabolism
- Vol. 259 (5) , E639-E643
- https://doi.org/10.1152/ajpendo.1990.259.5.e639
Abstract
Two methods of hand heating [warmed blanket 40 degrees C (WB) and warm-air box 55 degrees C (WA)] were compared with the effect of no heating (control) in six healthy females. After 30 min baseline, the left hand was either heated for 1 h or not heated. Measurements were made of skin temperature (ST), core temperature (CT), right forearm (FBF) and skin blood flow (SBF), and right forearm deep venous blood oxygen content with and without occlusion of the hand circulation. CT rose above baseline in WB (by +0.2 degrees C, P less than 0.01) but not with control or WA. Abdominal ST rose only with WB (by +0.66 degrees C above baseline, P less than 0.01). FBF increased above baseline values with both WA (by +10 ml.l forearm-1.min-1) and WB (by +12 ml.l forearm-1.min-1), but neither was significantly greater than the control. SBF increased above baseline only with WB (by +202 mV, P less than 0.01), and this was significantly greater than control SBF. With an occluded hand circulation, deep venous oxygen content rose above baseline values with WB only (+6.0%, P less than 0.01) but was not greater than control with either method of hand heating. We conclude that using a warm-air box has less effect than a heated blanket on the measured variables.This publication has 6 references indexed in Scilit:
- Measurement of forearm oxygen consumption: role of heating the contralateral handAmerican Journal of Physiology-Endocrinology and Metabolism, 1988
- Effects of arterial versus venous sampling on analysis of glucose kinetics in manJournal of Applied Physiology, 1976
- Deep body temperature from aural canal with servo-controlled heating to outer earJournal of Applied Physiology, 1975
- The effects of central body and trunk skin temperatures on reflex vasodilatation in the handThe Journal of Physiology, 1964
- MEASUREMENT OF BLOOD FLOW AND VOLUME IN THE FOREARM OF MAN; WITH NOTES ON THE THEORY OF INDICATOR-DILUTION AND ON PRODUCTION OF TURBULENCE, HEMOLYSIS, AND VASODILATATION BY INTRA-VASCULAR INJECTION 1Journal of Clinical Investigation, 1954
- The measurement of volume changes in human limbsThe Journal of Physiology, 1953