A conical implant–abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone
- 20 May 2003
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 14 (3) , 286-293
- https://doi.org/10.1034/j.1600-0501.2003.140306.x
Abstract
It has been hypothesized that marginal bone resorption may result from microdamage accumulation in the bone. In light of this, a dental implant should be designed such that the peak stresses arising in the bone are minimized. The load on an implant can be divided into its vertical and horizontal components. In earlier studies, it was found that the peak bone stresses resulting from vertical load components and those resulting from horizontal load components arise at the top of the marginal bone, and that they coincide spatially. These peak stresses added together produce a risk of stress-induced bone resorption. Using axisymmetric finite element analysis it was found that, with a conical implant-abutment interface at the level of the marginal bone, in combination with retention elements at the implant neck, and with suitable values of implant wall thickness and modulus of elasticity, the peak bone stresses resulting from an axial load arose further down in the bone. This meant that they were spatially separated from the peak stresses resulting from horizontal loads. If the same implant-abutment interface was located 2 mm more coronally, these benefits disappeared. This also resulted in substantially increased peak bone stresses.Keywords
This publication has 21 references indexed in Scilit:
- A Clinical, Radiographic, and Microbiologic Comparison of Astra Tech and Brånemark Single Tooth ImplantsClinical Implant Dentistry and Related Research, 2000
- The implant neck: smooth or provided with retention elements. A biomechanical approach.Clinical Oral Implants Research, 1999
- The use of a conical fixture design for fixed partial prostheses. A preliminary report.Clinical Oral Implants Research, 1998
- The effect of subcrestal placement of the polished surface of ITI® implants on marginal soft and hard tissuesClinical Oral Implants Research, 1996
- Single‐tooth replacement by osseointegrated Brånemark implants. A retrospective study of 82 implants.Clinical Oral Implants Research, 1995
- Predictable crestal bone remodelling around two porous‐coated titanium alloy dental implant designs. A radiographic study in dogs.Clinical Oral Implants Research, 1994
- Dental implant design–effect on bone remodelingJournal of Biomedical Materials Research, 1991
- Trabecular bone density and loading history: Regulation of connective tissue biology by mechanical energyJournal of Biomechanics, 1987
- Fatigue Behavior of Adult Cortical Bone: The Influence of Mean Strain and Strain RangeActa Orthopaedica, 1981
- Hard tissue as a composite material—I. Bounds on the elastic behaviorJournal of Biomechanics, 1971