Tissue fluid pressures: From basic research tools to clinical applications
- 1 November 1989
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 7 (6) , 902-909
- https://doi.org/10.1002/jor.1100070617
Abstract
The two basic research tools developed to measure tissue fluid pressure (wick catheter) and osmotic pressure (colloid osmometer) have undergone extensive validation and refinement over the past 20 years. Using these techniques, basic science investigations were undertaken of edema in Amazon reptiles, pressure‐volume relations in animals and plants, adaptive physiology of Antarctic penguins and fishes, edema in spawning salmon, tissue fluid balance in humans under normal conditions and during simulated weightlessness, and orthostatic adaptation in a mammal with high and variable blood pressures—the giraffe. Following and sometimes paralleling this basic research have been several clinical applications related to use of our colloid osmometer and wick technique. Applications of the osmometer have included insights into (a) reduced osmotic pressure of sickle‐cell hemoglobin with deoxygenation and (b) reduced swelling pressure of human nucleus pulposus with hydration or certain enzymes. Clinical uses of the wick technique have included (a) improvement of diagnosis and treatment of acute and chronic compartment syndromes, (b) elucidation of tissue pressure thresholds for neuromuscular dysfunction, and (c) development of a better tourniquet design for orthopaedics. This article demonstrates that basic research tools open up areas of basic, applied, and clinical research.Keywords
This publication has 49 references indexed in Scilit:
- Wide tourniquet cuffs more effective at lower inflation pressuresActa Orthopaedica, 1988
- Gravitational haemodynamics and oedema prevention in the giraffeNature, 1987
- Local compression patterns beneath pneumatic tourniquets applied to arms and thighs of human cadaveraJournal of Orthopaedic Research, 1987
- Delayed use of hyperbaric oxygen for treatment of a model anterior compartment syndromeJournal of Orthopaedic Research, 1986
- Long-term Myoneural Function After an Induced Compartment Syndrome in the Canine HindlimbPublished by Wolters Kluwer Health ,1985
- Long‐term measurement of muscle function in the dog hindlimb using a new apparatusJournal of Orthopaedic Research, 1983
- Skeletal Muscle Necrosis in Pressurized Compartments Associated with Hemorrhagic HypotensionPublished by Wolters Kluwer Health ,1980
- Intramuscular Pressures with Limb CompressionNew England Journal of Medicine, 1979
- THE TOURNIQUETAnz Journal of Surgery, 1978
- Edema in Spawning SalmonJournal of the Fisheries Research Board of Canada, 1975