Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle‐in‐cell approach
- 25 October 2007
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 21 (22) , 3527-3546
- https://doi.org/10.1002/rcm.3234
Abstract
Using a ‘Particle-In-Cell’ approach taken from plasma physics we have developed a new three-dimensional (3D) parallel computer code that today yields the highest possible accuracy of ion trajectory calculations in electromagnetic fields. This approach incorporates coulombic ion–ion and ion–image charge interactions into the calculation. The accuracy is achieved through the implementation of an improved algorithm (the so-called Boris algorithm) that mathematically eliminates cyclotron motion in a magnetic field from digital equations for ion motion dynamics. It facilitates the calculation of the cyclotron motion without numerical errors. At every time-step in the simulation the electric potential inside the cell is calculated by direct solution of Poisson's equation. Calculations are performed on a computational grid with up to 128 × 128 × 128 nodes using a fast Fourier transform algorithm. The ion populations in these simulations ranged from 1000 up to 1 000 000 ions. A maximum of 3 000 000 time-steps were employed in the ion trajectory calculations. This corresponds to an experimental detection time-scale of seconds. In addition to the ion trajectories integral time-domain signals and mass spectra were calculated. The phenomena observed include phase locking of particular m/z ions (high-resolution regime) inside larger ion clouds. A focus was placed on behavior of a cloud of ions of a single m/z value to understand the nature of Fourier transform ion cyclotron resonance (FTICR) resolution and mass accuracy in selected ion mode detection. The behavior of two and three ion clouds of different but close m/z was investigated as well. Peak coalescence effects were observed in both cases. Very complicated ion cloud dynamics in the case of three ion clouds was demonstrated. It was found that magnetic field does not influence phase locking for a cloud of ions of a single m/z. The ion cloud evolution time-scale is inversely proportional to magnetic field. The number of ions needed for peak coalescence depends quadratically on the magnetic field. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 52 references indexed in Scilit:
- Two ions in one trap: ultra-high precision mass spectrometry?IEEE Transactions on Instrumentation and Measurement, 2003
- Realistic simulation of the ion cyclotron resonance mass spectrometer using a distributed three-dimensional particle-in-cell codeJournal of the American Society for Mass Spectrometry, 1999
- Two dimensional many particle simulation of trapped ionsInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Prediction of a Space Charge Induced Upper Molecular Mass Limit Towards Achieving Unit Mass Resolution in Fourier Transform Ion Cyclotron Resonance Mass SpectrometryJournal of Mass Spectrometry, 1996
- Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometryPhysical Review E, 1995
- Dynamics of ion coupling in an FTMS ion trap and resulting effects on mass spectra, including isotope ratiosInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Peak Confluence Phenomenon in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.Journal of the Mass Spectrometry Society of Japan, 1994
- Limits to fourier transform—ion cyclotron resonance mass spectrometry for atomic mass measurementsInternational Journal of Mass Spectrometry and Ion Processes, 1990
- Geonium theory: Physics of a single electron or ion in a Penning trapReviews of Modern Physics, 1986
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984