Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI
Open Access
- 2 July 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (1) , 141-148
- https://doi.org/10.1002/mrm.1169
Abstract
Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice profiles of the inversion or saturation pulses. This article systematically examines through simulations the effects of slice profile imperfections on the perfusion signal for nine labeling schemes, including FAIR, FAIRER, and EST (UNFAIR). Each sequence is evaluated for quantitative accuracy, suppression of stationary signal, and magnitude of perfusion signal. Perfusion effects are modeled from a modified Bloch equation and experimentally determined slice profiles. The results show that FAIR, FAIRER, and EST have excellent tissue suppression. The magnitude of the perfusion signal is comparable for FAIR and FAIRER, with EST providing a slightly weaker signal. For quantitative measurements, all three methods underestimate the perfusion signal by more than 20%. Of the additional six ASL techniques examined, only one performed well in this model. This method, which combines inversion and saturation recovery, yields improved signal accuracy (<15% difference from the theoretical value) and tissue suppression similar to that of FAIR and its variants, but has only half the signal. Magn Reson Med 46:141–148, 2001.Keywords
This publication has 22 references indexed in Scilit:
- A model system for perfusion quantification using FAIRMagnetic Resonance Imaging, 2000
- Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR)Magnetic Resonance Imaging, 1997
- Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopyMagnetic Resonance in Medicine, 1996
- Mr perfusion studies with t1‐weighted echo planar imagingMagnetic Resonance in Medicine, 1995
- Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mappingMagnetic Resonance in Medicine, 1995
- Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.Radiology, 1994
- Measurement of rat brain perfusion by NMR using spin labeling of arterial water: In vivo determination of the degree of spin labelingMagnetic Resonance in Medicine, 1993
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equationPhysical Review A, 1985