Abstract
Thirteen patients were implanted with the Telectronics 4210 ATP implantable cardioverter defibrillator (ICD) for ventricular tachycardia or ventricular fibrillation. This device has multiprogrammable anfilachycardia pacing, bradycardia pacing, and shock therapies. In addition, there is extensive data Jogging and EGG snapshot capability for arrhythmia confirmation and response to therapy. These features permit easy retrieval of all detected and treated events, whatever the eventual outcome. In this study, the data logged at predischarge eleclrophysiological testing was compared to the data recorded in a standard manner. The bulk of the data, however, was derived from long‐term follow‐up of spontaneous events over a mean period of 203 days (range 154–257). During this period, a total of 6,193 arrhythmia detections were made: 20 were classified as ventricular fibrillation, and 6,173 as ventricular tachycardia. The vast majority of these (93%) terminated spontaneously without ICD intervention (5.738), underscoring the benefit of a standard second confirmation prior to therapy delivery (noncommitted system). There were 394 arrhythmia episodes treated with antitachycardia pacing; of these a total of 8.3% accelerated to either more rapid ventricular tachycardia or ventricular fibrillation (4.3% and 4.0%, respectively). Events were reported in an “episode log” format, listing all arrhythmia detections with time/date annotation; or in a “sense history” format, detailing each episode from start to conclusion. These data demonstrate that this advanced, “tiered” ICD with data recall contributes to better patient management, and permits a more tailored termination prescription for the individual patient.Keywords
This publication has 5 references indexed in Scilit:
- Efficacy of the automatic implantable cardioverter-defibrillator in prolonging survival in patients with severe underlying cardiac diseaseJournal of the American College of Cardiology, 1990
- Mechanism of Death in Patients with the Automatic Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1988
- Implantable Defibrillation: Eight Years Clinical ExperiencePacing and Clinical Electrophysiology, 1988
- Automatic Implantable Cardioverter Defibrillators and Survival of Patients with Left Ventricular Dysfunction and Malignant Ventricular ArrhythmiasAnnals of Internal Medicine, 1988
- Clinical treatment of life-threatening ventricular tachyarrhythmias with the automatic implantable defibrillatorAmerican Heart Journal, 1981