Elevated Temperature Degradation of a 50:50 Copolymer of PLA-PGA
- 1 December 1997
- journal article
- research article
- Published by Mary Ann Liebert Inc in Tissue Engineering
- Vol. 3 (4) , 345-352
- https://doi.org/10.1089/ten.1997.3.345
Abstract
In vitro degradation studies of devices fabricated from polylactic acid (PLA) and polyglycolic acid (PGA) are usually performed at the physiologic 37°C and often take long periods of time to complete. The objective of the present study was to examine the degradation of a 50:50 PLA-PGA copolymer over a wide temperature range (25°C to 80°C) and compare the degradation characteristics at temperatures below and above the polymer's glass transition temperature (Tg ). Samples were fabricated using a solvent-casting technique and subjected to degradation in phosphate-buffered saline at the different test temperatures (T) for different periods of time. At the end of each test period, the samples were examined for changes in mass and molecular weight. The pH of the degradation media was also measured. Using the Arrhenius equation, activation energies were calculated for the degradation reaction. The results indicated that the rates of change of mass and molecular weight increased with increasing test temperatures. Activation energies for the degradation reaction at temperatures below and above the Tg were distinctly different. Thus, it is recommended that tests performed at T > Tg should not be used to predict degradation behavior at T < Tg .Keywords
This publication has 20 references indexed in Scilit:
- Salient Degradation Features of a 50:50 PLA/PGA Scaffold for Tissue EngineeringTissue Engineering, 1996
- The Effects of Dynamic Compressive Loading on Biodegradable Implants of 50–50% Polylactic Acid–Polyglycolic AcidTissue Engineering, 1996
- Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid/ polyglycolic acid copolymersBiomaterials, 1996
- Fabrication and Characterization of PLA-PGA Orthopedic ImplantsTissue Engineering, 1995
- Protein release kinetics of a biodegradable implant for fracture non-unionsBiomaterials, 1995
- The effects of ultrasound irradiation on a biodegradable 50–50% copolymer of polylactic and polyglycolic acidsJournal of Biomedical Materials Research, 1994
- Structure-property relationships in the case of the degradation of massive poly(?-hydroxy acids) in aqueous mediaJournal of Materials Science: Materials in Medicine, 1990
- Structure-property relationships in the case of the degradation of massive poly(?-hydroxy acids) in aqueous mediaJournal of Materials Science: Materials in Medicine, 1990
- Structure-property relationships in the case of the degradation of massive aliphatic poly-(?-hydroxy acids) in aqueous mediaJournal of Materials Science: Materials in Medicine, 1990
- Biodegradable poly(lactic acid) polymersJournal of Biomedical Materials Research, 1971