Filtration des solutions aqueuses en vue du dosage des cations metalliques
- 1 June 1980
- journal article
- research article
- Published by Taylor & Francis in Environmental Technology Letters
- Vol. 1 (6) , 283-290
- https://doi.org/10.1080/09593338009383978
Abstract
It was found during the filtration of aqueous solutions containing metallic cations that a large part of these cations could be retained by fritted glass serving as a support for the filter. Additional tests have made it possible to determine the factors responsible for this retention. A method is given for avoiding this loss and, for the case where this procedure is not applicable, an indication is given of the filtration conditions allowing this loss to be minimized.Keywords
This publication has 1 reference indexed in Scilit: