Quantification of Pulsatility as a Function of Vascular Input Impedance: An In Vitro Study
- 1 March 2007
- journal article
- biomedical engineering
- Published by Wolters Kluwer Health in Asaio Journal
- Vol. 53 (2) , 115-121
- https://doi.org/10.1097/01.mat.0000250265.69542.80
Abstract
The physiological benefits of pulsatility generated by ventricular assist device (VAD) support continue to be heavily debated as application of VAD support has been expanded to include destination and recovery therapies. In this study, the relationship between input impedance (Zart) and vascular pulsatility during continuous flow (CF) or pulsatile flow (PF) VAD support was investigated. Hemodynamic waveforms were recorded at baseline failure and with 50%, 75%, and 100% CF or PF VAD support for nine different Zart test conditions (combination of three different resistance and compliance settings) in a mock circulatory system simulating left ventricular failure. High-fidelity hemodynamic pressure and flow waveforms were recorded to calculate mean arterial pressure (MAP), Zart, energy equivalent pressure (EEP), and surplus hemodynamic energy (SHE) as metrics for quantifying vascular pulsatility. MAP and EEP were elevated with increasing resistance whereas SHE was reduced with increasing compliance. Vascular pulsatility was restored with increasing PF VAD support, but diminished by up to 90% with increasing CF VAD support. The nonpulsatile energy component (MAP) of the pressure waveform is dependent on resistance whereas the pulsatile energy component (SHE) is dependent on compliance. The impact of Zart and vascular pulsatility on patient recovery with VAD support warrants further investigation.Keywords
This publication has 33 references indexed in Scilit:
- Energy Equivalent Pressure and Total Hemodynamic Energy Associated with the Pressure-Flow Waveforms of a Pediatric Pulsatile Ventricular Assist DeviceAsaio Journal, 2005
- Cellular and Hemodynamics Responses of Failing Myocardium to Continuous Flow Mechanical Circulatory Support Using the DeBakey-Noon Left Ventricular Assist Device: a Comparative Analysis With Pulsatile-Type DevicesThe Journal of Heart and Lung Transplantation, 2005
- Precise Quantification of Pressure Flow Waveforms of a Pulsatile Ventricular Assist DeviceAsaio Journal, 2005
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureNew England Journal of Medicine, 2001
- Invited commentaryThe Annals of Thoracic Surgery, 2001
- Defining Pulsatile Perfusion: Quantification in Terms of Energy Equivalent PressureArtificial Organs, 1999
- The Role of Pulsatility in End-Organ Microcirculation After Cardiogenic ShockAsaio Journal, 1996
- Improved Left Ventricular Function After Chronic Left Ventricular UnloadingThe Annals of Thoracic Surgery, 1996
- Effect of Pulsatile and Nonpulsatile Assist on Heart and Kidney Microcirculation with Cardiogenic ShockArtificial Organs, 1996
- LEFT VENTRICULAR SIMULATOR FOR CARDIOVASCULAR DEVICE TESTINGAsaio Journal, 1996