Prediction Method for Buried Pipeline Voltages Due to 60 Hz AC Inductive Coupling Part II--Field test Verification
- 1 May 1979
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. PAS-98 (3) , 788-794
- https://doi.org/10.1109/TPAS.1979.319291
Abstract
The results of field tests on a buried, 34-inch diameter gas pipeline adjacent to a 525 kV ac power transmission line for 54 miles are discussed. Comparison is made between measured inductive coupling data and predictions obtained using the theory developed in part I of this paper. An excellent agreement of the predicted and measured results is shown for the location and magnitude of all induced voltage peaks on the pipeline.Keywords
This publication has 0 references indexed in Scilit: