Abstract
X-ray diffraction study shows that an etching solution of 3% HF and 5% HNO3 is the most suitable solution for preparing a bioactive surface layer of HA-glass-titanium composite, since the glass is removed, a great number of HA particles are exposed, and little CaF2 is produced by the etching. Anodic polarization measurement demonstrates that the 3-min etching gives an electrochemically active surface of the composites. These results and SEM observations suggest that this solution provides an adequate surface of the composite for the dental and medical implants.Keywords
This publication has 14 references indexed in Scilit:
- Micro-observation and characterization of bonding between bone and HA-glass-titanium functionally gradient compositeBiomaterials, 1991
- Electrochemical corrosion behaviour of hydroxyapatite-glass-titanium compositeBiomaterials, 1991
- Dissolution of Hydroxyapatite-Glass-Titanium Composite and HAP-Precipitation on Surface in vitroJapanese Journal of Applied Physics, 1990
- Effects of Inorganic Orthophosphate and Pyrophosphate on Dissolution of Calcium Fluoride in WaterJournal of Dental Research, 1988
- Plasma sprayed coatings of hydroxylapatiteJournal of Biomedical Materials Research, 1987
- Compositional dependence of formation of an apatite layer on glass-ceramics in simulated physiological solutionJournal of Materials Science, 1987
- Bonding between Bioactive Glasses, Glass-Ceramics or Ceramics in a Simulated Body FluidJournal of the Ceramic Association, Japan, 1987
- Structural analysis of hydroxyapatite coatings on titaniumBiomaterials, 1986
- Tissue response to dense apatite implants in ratsJournal of Biomedical Materials Research, 1980
- Bioceramics consisting of calcium phosphate saltsBiomaterials, 1980