Digital Storage and Analysis of Color Doppler Echocardiograms
- 1 January 1997
- journal article
- Published by Wiley in Echocardiography
- Vol. 14 (1) , 91-102
- https://doi.org/10.1111/j.1540-8175.1997.tb00696.x
Abstract
Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.Keywords
This publication has 32 references indexed in Scilit:
- Digital compression of echocardiograms: Impact on quantitative interpretation of color doppler velocityJournal of the American Society of Echocardiography, 1996
- Automated flow rate calculation based on digital analysis of flow convergence proximal to regurgitant orificeJournal of the American College of Cardiology, 1993
- Quantification of mitral regurgitation with the proximal flow convergence method: A clinical studyAmerican Heart Journal, 1992
- Left ventricular flow propagation during early filling is related to wall relaxation: A color M-mode Doppler analysisJournal of the American College of Cardiology, 1992
- ECHOCARDIOGRAPHY IN DIAGNOSIS OF AORTIC DISSECTIONThe Lancet, 1989
- Spatial velocity distribution and acceleration in serial subvalve tunnel and valvular obstructions: An in vitro study using doppler color flow mappingJournal of the American College of Cardiology, 1989
- Instrumentation and physical factors related to visualization of stenotic and regurgitant jets by Doppler color flow mappingJournal of the American College of Cardiology, 1988
- In vitro methods for studying the accuracy of velocity determination and spatial resolution of a color Doppler flow mapping systemAmerican Heart Journal, 1987
- Evaluation of aortic insufficiency by Doppler color flow mappingJournal of the American College of Cardiology, 1987
- Doppler echocardiographic features of ventricular septal rupture in myocardial infarctionJournal of the American College of Cardiology, 1985