Unequivocal determination of metal atom oxidation state in naked heme proteins: Fe(III)myoglobin, Fe(III)cytochrome c, Fe(III)cytochrome b5, and Fe(III)cytochrome b5 L47R
- 1 February 2000
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 11 (2) , 120-126
- https://doi.org/10.1016/s1044-0305(99)00132-4
Abstract
Unambiguous determination of metal atom oxidation state in an intact metalloprotein is achieved by matching experimental (electrospray ionization 9.4 tesla Fourier transform ion cyclotron resonance) and theoretical isotopic abundance mass distributions for one or more holoprotein charge states. The iron atom oxidation state is determined unequivocally as Fe(III) for each of four gas-phase unhydrated heme proteins electrosprayed from H2O: myoglobin, cytochrome c, cytochrome b5, and cytochrome b5 L47R (i.e., the solution-phase oxidation state is conserved following electrospray to produce gas-phase ions). However, the same Fe(III) oxidation state in all four heme proteins is observed after prior reduction by sodium dithionite to produce Fe(II) heme proteins in solution: thus proving that oxygen was present during the electrospray process. Those results bear directly on the issue of similarity (or lack thereof) of solution-phase and gas-phase protein conformations. Finally, infrared multiphoton irradiation of the gas-phase Fe(III)holoproteins releases Fe(III)heme from each of the noncovalently bound Fe(III)heme proteins (myoglobin, cytochrome b5 and cytochrome b5 L47R), but yields Fe(II)heme from the covalently bound heme in cytochrome c.Keywords
This publication has 38 references indexed in Scilit:
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Ion/ion chemistry of high-mass multiply charged ionsMass Spectrometry Reviews, 1998
- High resolution ion mobility measurements for gas phase proteins: correlation between solution phase and gas phase conformationsInternational Journal of Mass Spectrometry and Ion Processes, 1997
- Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applicationsInternational Journal of Mass Spectrometry and Ion Processes, 1996
- Direct Sequence Data from Heterogeneous Creatine Kinase (43 kDa) by High-Resolution Tandem Mass SpectrometryBiochemistry, 1995
- Cyclotron motion of two Coulombically interacting ion clouds with implications to Fourier-transform ion cyclotron resonance mass spectrometryPhysical Review E, 1995
- Characterization of Cytochrome c Variants with High-Resolution FTICR Mass Spectrometry: Correlation of Fragmentation and StructureAnalytical Chemistry, 1995
- Observation of intact (heme‐bound) myoglobin by electrospray ionization on a double‐focusing mass spectrometerRapid Communications in Mass Spectrometry, 1993
- The correct molecular weight of myoglobin, a common calibrant for mass spectrometryRapid Communications in Mass Spectrometry, 1992
- Ion-molecule clusters involving doubly charged metal ions (M2+)International Journal of Mass Spectrometry and Ion Processes, 1990