Incidence of ICD Lead Related Complications During Long‐Term Follow‐Up: Comparison of Epicardial and Endocardial Electrode Systems
- 1 November 1995
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 18 (11) , 2053-2061
- https://doi.org/10.1111/j.1540-8159.1995.tb03867.x
Abstract
The aim of this study was to evaluate the longterm stability of epicardial and endocardial lead systems for third‐generation cardioverter defibrillators (ICDs) and to assess the usefulness of diagnostic tools. One hundred forty patients with 61 epicardial (43.6%) and 79 nonthoracotomy systems (56.4%) were followed for 2 5 ± 19 months. A total of 18 (12.9%) lead related complications were documented. Complications of epicardial systems were detected in 10 patients (16.4%) during a follow‐up time of 36 ± 8 months: crinkling of patch electrodes in 6 patients (9.8%), insulation breakage of sensing electrodes in 2 patients (3.3%), and adapter defect in 2 patients (3.3%). Eight of the patients (10.1%) with transvenous‐subcutaneous systems had lead related complications during a 13 ± 6 months follow‐up: fracture of the subcutaneous patch lead in 2 patients (2.5%), dislodgment of the right ventricular lead in 2 patients (2.5%), dislodgment of the superior vena cava lead in 2 patients (2.5%), insulation breakage of sensing electrodes in 1 patient (1.3%), and connector defect in 1 patient (1.3%). There was no significant difference in the incidence of lead related complications between epicardial and endocardial systems (P > 0.05). Fractures, dislodgments, and crinklings were documented within the first 8 ± 5 months by regular chest X ray. Defects of insulation, adapter, or connector were detected 22 ± 10 months after implantation and were associated with delivery of multiple inappropriate ICD therapies. An operative lead revision was indicated for 4 epicardial (6.6%) and 6 endocardial (7.6%) lead systems. Conclusions: Endocardial lead systems offer a similar long‐term stability as compared to epicardial had systems. Chest X ray is the most useful tool to detect lead fracture, dislodgment. and patch crinkling. Marker recordings or real‐time electrograms have not been helpful in this series to identify patients with suspected lead defects prior to the experience of inappropriate ICD discharges.Keywords
This publication has 19 references indexed in Scilit:
- Implantable transvenous cardioverter-defibrillators.Circulation, 1993
- Failure of One Conductor in a Nonthoracotomy Implantable Defibrillator Lead Causing Inappropriate Sensing and Potentially Ineffective Shock DeliveryPacing and Clinical Electrophysiology, 1993
- Initial Experience with Transvenous Implantable Cardioverter Defibrillator Lead Systems: Operative Morbidity and MortalityPacing and Clinical Electrophysiology, 1993
- Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system.Circulation, 1992
- A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.Circulation, 1992
- Management of complications associated with a first-generation endocardial defibrillation lead system for implantable cardioverter-defibrillatorsThe American Journal of Cardiology, 1990
- The Automatic Implantable Cardioverter-Defibrillator: Efficacy, Complications, and Device FailuresAnnals of Internal Medicine, 1986
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985
- Automatic Implantable Cardioverter‐Defibrillator Structural CharacteristicsPacing and Clinical Electrophysiology, 1984
- The Automatic Implantable DefibrillatorPacing and Clinical Electrophysiology, 1982