Early detection of prosthetic-hip loosening: Comparison of low- and high-viscosity bone cement
- 1 January 1990
- journal article
- case report
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 61 (3) , 273-274
- https://doi.org/10.3109/17453679008993518
Abstract
In 1987, we reported the 1-year migration of the prosthetic components in 16 hips followed by roentgen stereophotogrammetry after fixation with either low- or high-viscosity cement. We now report the migration of these prosthetic components during another 2 postoperative years. Eight acetabular components, four in each group, migrated cranially; and four femoral components, three in the low-viscosity and one in the high-viscosity group, migrated distally. All but two migrations were obvious 4 months postoperatively, which indicates that what is called late loosening is the result of late detection rather than of late occurrence of loosening. Low-viscosity cement did not provide improved prosthetic fixation.Keywords
This publication has 2 references indexed in Scilit:
- Roentgen stereophotogrammetryActa Orthopaedica, 1989
- Low- versus high-viscosity bone cement: Fixation of hip prostheses analyzed by roentgen stereophotogrammetryActa Orthopaedica, 1987