Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter
- 1 June 1981
- journal article
- research article
- Published by Oxford University Press (OUP) in Cardiovascular Research
- Vol. 15 (6) , 328-334
- https://doi.org/10.1093/cvr/15.6.328
Abstract
To improve assessment of ventricular function during cardiac catheterisation there should be available a continuous registration of stroke volume and cardiac output in addition to ventricular pressure. To obtain the desired volumetric quantities a catheter has been developed which measures changes in intraventricular dimensions by electrical impedance. For this purpose, the catheter is equipped with eight electrodes spaced over a distance equal to the long axis of the left ventricle into which it is introduced. A constant current is imposed between the outermost electrodes while the inner six are used to measure resistance of volume segments of the blood contained within the ventricular cavity. The difference in resistance at the beginning and end of ejection is proportional to the contribution of each segment to stroke volume, which follows from addition of the segmental terms. Calibration is obtained by measuring electrical conductivity of a blood sample. The catheter was tested over a tenfold range of cardiac output, both in vitro, using an artificial heart model, while performance in vivo was evaluated in 12 dogs. In the animal study, stroke volume and cardiac output from the catheter were compared with flows obtained with an electromagnetic flowmeter. In both studies, linear regression analysis showed excellent correlation of cardiac output (r = 0.99, n = 10 in vitro, r = 0.95, n = 126 in vivo) while the regression equations were close to those of identity. Very good correlation (r = 0.98, n = 28) was also obtained for stroke volumes on a beat to beat basis during arrhythmia. It is concluded that the catheter, which has great potential for application in man, fulfills its primary aim of continuously recording stroke volume and cardiac output.This publication has 5 references indexed in Scilit:
- The three-dimensional dynamic geometry of the left ventricle in the conscious dog.Circulation Research, 1976
- Resistivity of Body Tissues at Low FrequenciesCirculation Research, 1963
- Intracardiac Impedance PlethysmographyAmerican Journal of Physiology-Legacy Content, 1953
- The Origin of the Variations of Body Impedance Occurring during the Cardiac CycleCirculation, 1952
- EFFECT OF MOTION ON THE ELECTRICAL CONDUCTIVITY OF THE BLOODAmerican Journal of Physiology-Legacy Content, 1937