Remodeling of an acellular collagen graft into a physiologically responsive neovessel
- 1 November 1999
- journal article
- research article
- Published by Springer Nature in Nature Biotechnology
- Vol. 17 (11) , 1083-1086
- https://doi.org/10.1038/15062
Abstract
Surgical treatment of vascular disease has become common, creating the need for a readily available, small-diameter vascular graft. However, the use of synthetic materials is limited to grafts larger than 5–6 mm because of the frequency of occlusion observed with smaller-diameter prosthetics. An alternative to synthetic materials would be a biomaterial that could be used in the design of a tissue-engineered graft. We demonstrate that a small-diameter (4 mm) graft constructed from a collagen biomaterial derived from the submucosa of the small intestine and type I bovine collagen has the potential to integrate into the host tissue and provide a scaffold for remodeling into a functional blood vessel. The results obtained using a rabbit arterial bypass model have shown excellent hemostasis and patency. Furthermore, within three months after implantation, the collagen grafts were remodeled into cellularized vessels that exhibited physiological activity in response to vasoactive agents.Keywords
This publication has 22 references indexed in Scilit:
- Magnetically orientated tissue-equivalent tubes: application to a circumferentially orientated media-equivalentBiomaterials, 1996
- A hybrid vascular model biomimicking the hierarchic structure of arterial wall: Neointimal stability and neoarterial regeneration process under arterial circulationThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Superior late patency of small-diameter dacron grafts seeded with omental microvascular cells: An experimental studyThe Annals of Thoracic Surgery, 1994
- Endothelial Cell Transplantation onto Polymeric Arteriovenous Grafts Evaluated Using a Canine ModelJournal of Investigative Surgery, 1994
- Coronary angioplasty in the United Kingdom. Report of a Working Party of the British Cardiac Society.Heart, 1991
- Effect of albumin coating on the in vitro blood compatibility of Dacron® arterial prosthesesBiomaterials, 1989
- Heparin immobilization onto segmented polyurethaneurea surfaces—effect of hydrophilic spacersJournal of Biomedical Materials Research, 1988
- A quantitative and qualitative comparison of fibrin glue, albumin, and blood as agents to pretreat porous vascular graftsJournal of Surgical Research, 1987
- A Blood Vessel Model Constructed from Collagen and Cultured Vascular CellsScience, 1986
- Correlation of operative findings with angiographic and noninvasive hemodynamic factors associated with failure of polytetrafluoroethylene graftsJournal of Vascular Surgery, 1984